| Specification |
After-sales Service: After-Sale Repairing, Technical Support;
Principle: Piezoelectric Type;
Range: 0-15m;
Measurement Accuracy: ±8mm;
Accuracy: 0.2%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Material: SS304;
Process Temperature: -40~120℃;
|
After-sales Service: 12 Months;
Range: 0-30m;
Accuracy: 0.25%;
Kind: Ultrasonic Wave;
Structure: All in One;
Warranty: 1 Year;
Process Temperature: -20℃~80℃;
Measuring Range: 0-25m;
Measuring Media: Liquid;
Output Signal: 4~20mA,0~10V,0~5V , RS485;
Power Supply: DC24V,AC220V;
Electrical Connection: M18*1.5;
Measuring Probe: ABS,PVC, PTFE Optional;
Protection Grade: IP68;
Display: LCD;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Kind: Liquid Level Transmitter;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD D;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|
After-sales Service: 24 Hours Online Service;
Principle: The Principle of Static Pressure Difference;
Range: 4~20mA;
Measurement Accuracy: ±3mm;
Accuracy: 0.1%;
Structure: All in One;
Warranty: 1 Year;
Material: Customizable;
Process Temperature: -40 to 85℃, -35 to 85℃ When Equipped with an LCD;
Scope of Use: Liquids, Gases and Vapors;
Power Supply: DC 12-45V; Hart;
Storage Temperature: -45 to 90℃;
Basic Error: ±0.075%, 0.1%, 0.2%;
End-Base Consistency Error: ±0.1%, 0.2%, 0.3%;
Repeatability Error: 0.1%, 0.2%, 0.3%;
Hysteresis: 0.1%, 0.2%, 0.3%;
Constant Current Performance: The Variation Is Less Than 0.075%;
Measuring Medium: Liquid, Oil, Corrosive Liquid;
Splint Material: All 316L Stainless Steel;
|