| Specification |
Type: Air Handling Unit;
Air Tube Material: Galvanized Sheet;
Corrosion Durability: Higher;
Operating Voltage: 380/400 VAC;
Noise Level: Low;
Application Fields: Air-Conditioning (HVAC)System;
Mounting: Floor Standing;
Lifetime: >20 years;
Condition: New;
Optional 1: VSD, VFD;
Ahu Panels: Painted Steel, Gi, Ss Panels;
Cooling/ Heating Coil 1: Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr;
Fan: Belt Drive Centrifugal Fan, Plug Fan,Ec Fan;
Side Sliding Filter with Tracks: Yes;
PU Foam Insulation: 43-48kg/M3;
Cold Bridge Free Design: Yes;
Filters: Pre-Filter, Bag Filter, HEPA Filter;
Ahu Framework: Aluminum;
Base: C-Channel Hot DIP Base;
Ahu Construction: 25mm/ 50mm/ 75mm Double Skin;
Optional 2: Heat Recovery Wheel;
Control: Option for PLC, Ddc;
Cooling/ Heating Coil 2: Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame;
Optional 3: Ep, Chemical Filter, Plasma Sterilizer, Ak;
|
Type: Fan Coil Unit;
Air Tube Material: Galvanized Sheet;
Corrosion Durability: Higher;
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH;
Noise Level: Low;
Application Fields: Restaurant/Hotel Room/Villa;
Mounting: Ceiling Concealed;
Lifetime: >20 years;
Condition: New;
Pipe System: Two Pipe System;
Air Outlet Static Pressure: 0, 12, 30PA;
Motor: BLDC, Ec;
Production Time: 20 Days for Bulk Order;
Air Return: Backward/Downward;
Rows: 2 and 3 Rows;
Main Usage: Chiller, Heat Pump, Underfloor Heating;
|
Type: Fan Coil Unit;
Air Tube Material: Galvanized Sheet;
Corrosion Durability: Higher;
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH;
Noise Level: Low;
Application Fields: Restaurant/Hotel Room/Villa;
Mounting: Ceiling Concealed;
Lifetime: >20 years;
Condition: New;
Motor: BLDC, Ec;
Pipe System: Two Pipe System;
Air Outlet Static Pressure: 0, 12, 30PA;
Production Time: 20 Days for Bulk Order;
Air Return: Backward/Downward;
Rows: 2 and 3 Rows;
Main Usage: Chiller, Heat Pump, Underfloor Heating;
|
Type: Fan Coil Unit;
Air Tube Material: Galvanized Sheet;
Corrosion Durability: Higher;
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH;
Noise Level: Low;
Application Fields: Restaurant/Hotel Room/Villa;
Mounting: Ceiling Concealed;
Lifetime: >20 years;
Condition: New;
Production Time: 20 Days for Bulk Order;
Motor: BLDC, Ec;
Main Usage: Chiller, Heat Pump, Underfloor Heating;
Pipe System: Two Pipe System;
Air Outlet Static Pressure: 0, 12, 30PA;
Air Return: Backward/Downward;
Rows: 2 and 3 Rows;
|
Type: Fan Coil Unit;
Air Tube Material: Galvanized Sheet Casing, ABS Air Grille;
Corrosion Durability: Higher;
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH;
Noise Level: Low;
Application Fields: Restaurant/Hotel Room/Meeting Room/Office;
Mounting: Ceiling Mount;
Lifetime: >20 years;
Condition: New;
Installation: Ceiling Mounted /Floor Standing;
Production Time: 20 Days for Bulk Order;
Motor: DC,Ec;
Thermostat: 0~10V Stepless (3 Speed Control Is Optional);
Air Return: Front/Downward;
Pipe System: Two Pipe and Four Pipe System;
Main Usage: Chiller, Heat Pump, Underfloor Heating;
|