| Specification |
Customized: Non-Customized;
IP Rating: IP65;
Screen Size: No Screen;
SD Card Memory Size: 1MB;
Measuring Medium: Temperature;
Type: Paperless Logger;
Bluetooth Module: Bluetooth 5.0 Nrf52840;
Distance Range: 300meters in Open Area;
Application: Food, Fruit,Vegeatble, Drugs,Cold Chain;
Battery Capacity: 1350mAh;
Working Temperature: -20 C to 60 C;
Operating Humidity: 20%~80%Rh;
Voltage: 3.7V DC;
Broadcast Intervals: 5seconds;
Collect Interval: 60 Seconds;
Saving Intervals: 300 Seconds;
Case Color: Grey;
Red Light Indicator: Temperature Alarm;
Blue Light Indicator: Device Work Normally;
Standby Current: 16ua;
Peak Current: 45mA;
|
Warranty: 1 Year;
Product Name: Soil Moisture Data Logger;
Measurement Method: Volumetric Water Content;
Temperature Range: -40~80℃;
Conductivity: 0-20000us/Cm;
Temperature Accuracy: + 0.5;
Moisture Accuracy: +3%(When Moisture Is Less Than 53%);
Conductivity Accuracy: + 3%;
Response Time: Less Than 2 Seconds;
Application: Soil Moisture Data Logger;
|
Usage: Temperature Sensor;
Product Name: Data Logger;
Humidity: 0~100%Rh;
Power Supply: Lithium-Ion Battery;
Accuracy: ±3%;
Resolution: 0.1%;
Working Temperature: -20℃~80℃;5%Rh~95%Rh;
Application: Soil Moisture Measurement;
Communication: USB;
Storage: 20000 Data;
|
After-sales Service: After-Sales Service Provided;
Warranty: After-Sales Service Provided;
Customized: Customized;
IP Rating: IP67;
Probe Measuring Range: Humidity 0%~100%Rh, Temp -40℃ ~85℃;
Resolution: 0.1%Rh Typically, 0.1℃;
Data Capacity: Capacity 34560;
Usage: Multiple Times;
Start Mode: Button Start or Timed Start;
Recording Interval: User Configurable (10 Seconds to 99 Hours);
Start Delay: User Configurable (0~ 72 Hours);
Alarm Range: User Configurable;
Alarm Type: Single Type, Cumulative Type;
Alarm Delay User Configurable (10 Second: User Configurable (10 Seconds to 99 Hours);
Form of Report: Pdf and Csv Format Data Report;
|
After-sales Service: After-Sales Service Provided;
Warranty: After-Sales Service Provided;
Customized: Customized;
IP Rating: IP67;
Probe Measuring Range: Humidity 0%~100%Rh, Temp -40℃ ~85℃;
Resolution: 0.1%Rh Typically, 0.1℃;
Data Capacity: Capacity 34560;
Usage: Multiple Times;
Start Mode: Button Start or Timed Start;
Recording Interval: User Configurable (10 Seconds to 99 Hours);
Start Delay: User Configurable (0~ 72 Hours);
Alarm Range: User Configurable;
Alarm Type: Single Type, Cumulative Type;
Alarm Delay User Configurable (10 Second: User Configurable (10 Seconds to 99 Hours);
Form of Report: Pdf and Csv Format Data Report;
|