| Specification |
Classification: Physiological Functions of Diagnosis and Monitoring Equipment;
Type: Urine Analyzer;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: All;
Product Name: Auto Coagulation Analyzer;
Power Supply: AC100~240V, 50/60Hz;
Measuring Principle: Infrared Sensor;
Analysis Result: Westergren ESR Value(mm/Hr);
Throughput: up to 80 Samples Per Hour;
Reading Channels: 20;
Loading Capacity: 20 Samples at Same Time;
Loading Pattern: Random;
Measuring Time: 30 Minutes or 60 Minutes Selectable;
Lighting: LED;
Model Number: Ea20;
Brand Name: Biobase;
Warranty: 1 Year;
Instrument Classification: Class II;
After-Sale Service: Online Technical Support;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Model No.: Bk-400;
Sample Positions: 37 Sample Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Cuvettes: Cuvettes;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Reagent Position: 28 Reagent Positions;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Features: 200 Sample Positions.;
Throughput: 600 Tests/Hour;
Wavelength: 340,405,450,510,546,578,630,700nm;
Humidity: 30-80%;
External Size (W*D*H): 625*425*460mm;
Net Weight: 36kg;
Absorbance: 0~3.0ABS;
Quality Control: Real-Time QC, Westgard Multi Rule, Cumulative Sum;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: Middle-aged and Old;
Model No.: Bk-200;
Sample Positions: 37 Sample Positions;
Probe Washing: Automatic Washing Interior and Exterior;
Cuvettes: Cuvettes;
Analysis Method: End-Point, Fixed-Time, Rate(Kinetic);
Reagent Position: 28 Reagent Positions;
Reagent Cooling: Refrigerated Tray with Independent Switch;
Features: 200 Sample Positions.;
Throughput: 600 Tests/Hour;
Wavelength: 340, 405, 450, 510, 546, 578, 630, 700nm;
Humidity: 30-80%;
External Size (W*D*H): 625*425*460mm;
Net Weight: 36kg;
Absorbance: 0~3.0ABS;
Quality Control: Real-Time QC, Westgard Multi Rule, Cumulative Sum;
|
Classification: Biological Diagnostics;
Type: Biochemistry Analyzer;
Group: All;
Model: Bth-V;
Temperature Range: Rt~90℃;
Temperature Precision: ±2℃;
Over Temperature Alarm Range: 1~5℃;
External Size: 500*330mm*180mm;
Water Tank Size: 220*150mm*65mm;
Drying Plate Size: 260*150mm;
Power: ≤450 W;
Power Supply: Standard: 220V 50/60Hz, Optional: 110V 50/60Hz;
Packing Size: 560*395*220mm;
Gross Weight: 10kg;
Warranty: 1 Year;
Place of Origin: Shandong, China;
Customized Support: OEM, Obm;
Brand Name: Biobase;
|