| Specification |
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv,7.2/30/60kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement, Harvesting Energy;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Open Circuit Protection: Yes;
Output Short Circuit Protection: Yes;
Ripple and Noise: <1%;
Voltage Accuracy: -1%~1%;
Load Adjustment Rate: -1%~1%;
Overheating Protection: Yes;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Harvesting Energy;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Structure: Whole & Split;
Material: Silicon Steel;
Operating Temperature: -30~120ºC;
Lead Time: 7-30 Working Days;
|
Application: Instrument, Measurement and Protection;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Measurement and Protection;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Type of Current Transformer: Indoor Use, Epoxy Resin, Sealed Structure;
Rated Voltage: 24kv;
Applicable Standard: IEC60044-1, IEC61869-2;
Combined Accuracy Classes: 0.2/10p10, 0.5/10p10;
|
Application: Instrument, Measurement and Protection;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Measurement and Protection;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Type of Current Transformer: Indoor Use, Epoxy Resin, Sealed Structure;
Rated Voltage: 24kv;
Applicable Standard: IEC60044-1, IEC61869-2;
Combined Accuracy Classes: 0.2/10p10, 0.5/10p10;
|