| Specification |
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage Radio: 10√3/0.1√3/0.1/ 3;
Rated Output: 15/50,30/50;
Itimate Output: 200;
Rated Insulationlevel: 12/42/75;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 10kv;
Rated Frequency: 50Hz or 60Hz;
Ambient Temperature: Maximum +40; Minimum -5;
Surface Creepage Distance: Greater Than 230mm;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting, Power Distribution;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Power Distribution;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Voltage: 10kv;
Rated Frequency: 50Hz 60Hz;
Rated Primary Current: From 5A to 1000A;
Accuracy Class and Combination: Common Accuracy Classes Include 0.2/10p10, 0.5/10p;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy Class & Error Limits: 0.2s 0.5;
Rated Parameters: Primary Current: 5A–3000A; Secondary Current;
Example Model: Lzzbj9-10;
Thermal & Dynamic Stability: Short-Time Withstand Current (1s or 4s).;
|