| Specification |
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy: 0.5%, 0.5s, 1%;
Standards: GB1208-2006;IEC 60044-1;Ntc 2205;
Safety Factor Rating: < 10;
Rated Frequency: 50Hz or 60Hz;
Environment: Outdoors or Indoors;
Rated Secondary Current: 5A or 1A;
Secondary Winding Power Frequency Withst: 3kv/1min;
Types: Outdoor Current Transformer;
Weight: 2.1kg;
Ratio: 100-1500A/5A;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Capacitive Type;
Accuracy: 0.5%;
Standards: IEC 60044-1;Ntc 2205; IEC61869-2;
Safety Factor Rating: < 10;
Rated Frequency: 50Hz or 60Hz;
Environment: Outdoors or Indoors;
Rated Secondary Current: 5A or 1A;
Types: Ring Type Current Transformer CT;
Weight: 3.8kg;
Output Signal: 10m Cable;
Color: Black and Orange;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy: 0.5%, 0.5s, 1%;
Standards: IEC61869-2, GB1208-2006;IEC 60044-1;Ntc 2205;
Safety Factor Rating: <10;
Rated Frequency: 50Hz or 60Hz;
Environment: Outdoors or Indoors;
Rated Secondary Current: 5A or 1A;
Secondary Winding Power Frequency Withst: 3kv/1min;
Weight: 2kg;
Types: Ring Core Current Transformer;
Installations: Outdoor or Indoor;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type, Suspension;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Current Range: 0-120A or 0-200A;
Diameter: 16mm;
Dimensions: 38mmx55mmx18mm;
Load Capacity: <4 Ohms;
Output Mode: 2.5m Lead Output;
Class: 0.2, 0.5, 1;
Types: 333mv Split Core Current Transformer;
Weight: 60g;
Working Temperature: -40-70 Deg;
Output Signal: 0-333mv AC;
|