| Specification |
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Free Hanging (in-Line;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Materil of Core: Laminated Silicon Steel;
Opening Size: 24mm;
Input: 200A;
Output: 20mA;
Accuracy: 0.5% or 0.2%;
Output Type: Cable;
Rated Voltage: 720V;
Rated Frequency: 50-60Hz;
Operating Temperature: -25℃ ~ +60℃;
Storage Temperature: -30℃ ~ +90℃;
Certificates: CE/RoHS/Reach/ISO9001;
Color: Black;
|
Application: Instrument, Position Sensor, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Altitude: Should Not Exceed 4000m;
Air Relative Humidity: ≤85%;
Air Relative Site: Outdoors.;
Insulation Level: 40.5/95/200kv;
|
Application: Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
|
Application: Instrument, Position Sensor, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Altitude: Should Not Exceed 4000m;
Insulation Level: 40.5/95/200kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: Cosφ=0.8(Lag);
Air Relative Site: Outdoors;
|
Application: Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 40.5/95/200kv;
Altitude: Should Not Exceed 4000m;
Air Relative Site: Outdoors;
Power Factor: Cosφ=0.8(Lag);
Rated Frequency: 50Hz or 60Hz;
Ambient Temperature: -40℃~+40℃;
|