| Specification |
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Charging Equipment Current Sensing;
IP Rating: IP44;
Customized: Customized;
Rated Input: 50/100/200/300A;
Measuring Range: 0~+-900A;
Supply Voltage: DC +-12~18V;
Output Current: +-50/100mA;
Offset Current: @IP=0, T=25°C < +-0.2mA;
Power Consumption: 15mA;
Primary Through-Hole: D20.2+-0.15mm;
Plastic Material: PBT G30/G15, UL94-V0;
|
Type: Electromagnetic;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Ad, DSP, PLC, Energy Meter;
IP Rating: IP40;
Customized: Customized;
Input Current: AC or DC;
Primary Input Current: 0-2000A;
Secondary Output Current: 50mA/100mA, 200mA, 400mA;
Auxiliary Power: +12V/15V/24V, -12V/15V/24V;
|
Type: Rogowski Coil Integrator;
Output Signal Type: 5A AC;
Production Process: Integration;
Material: Plastic and PCB Circuits;
Accuracy Grade: 0.5G;
Application: Integrator, Transducer, Current Probe;
IP Rating: IP20;
Customized: Customized;
Product Name: Rogowski Coil Integrator;
Mounting Type: Single Phase DIN-Rail;
Rated Output: 5A AC RMS;
Current Range: 100A, 600A, 1000A,3000A,6000A...50ka;
Current Sensor: Rogowski Coil;
Compatible Device: Energy Meter, Power Meter, Power Analyzer;
Site: Industrial Electrical Control, Plants;
Function 1: Power Monitoring & Analysis;
Function 2: Large Current/Harmonics/ Transients Monitoring;
Function 3: Welding Machine Control, Lab Instrument;
Power Supply: 24V DC;
Read Accuracy: 0.5%;
Phase Error: 0.5;
Linearity: 0.2%;
Power Consumption: Less Than 15W;
|
Type: Hall Type;
Output Signal Type: Digital Output;
Production Process: Injection;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Test and Measurement Equipment;
IP Rating: IP44;
Customized: Non-Customized;
Measuring Frequency: 0-100kHz;
Accuracy: 0.2%-1%;
Linearity: 0.1%;
High Isolation: Between Primary Current and Seconda;
Manufactured by: Close-Loop Hall Magnetic Compensation Principle;
Applications 1: High-Power Inverter, Medical Electronics, Test;
Application 2: Process Control Equipment Sound Equipment Specific;
Features: Wide Frequency Bandt No Insertion Loss;
Closed Loop Hall Current Sensor: AC Hall Effect Current Sensor;
Lem Hall Effect Current Sensor: Current Transformer Sensor;
|
Type: Hall Type;
Output Signal Type: Digital Output;
Production Process: Injection;
Material: Metal;
Accuracy Grade: 0.5G;
Application: Test and Measurement Equipment;
IP Rating: IP44;
Customized: Non-Customized;
Measuring Frequency: 0-100kHz;
Accuracy: 0.2%-1%;
Linearity: 0.1%;
High Isolation: Between Primary Current and Seconda;
Manufactured by: Close-Loop Hall Magnetic Compensation Principle;
Applications 1: High-Power Inverter, Medical Electronics, Test;
Application 2: Process Control Equipment Sound Equipment Specific;
Features: Wide Frequency Bandt No Insertion Loss;
Closed Loop Hall Current Sensor: AC Hall Effect Current Sensor;
Lem Hall Effect Current Sensor: Current Transformer Sensor;
|