| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Pole: Single;
Rated Voltage: AC230/400V;
Tripping Curve: B, C, D;
Rated Breaking Capacity: 6000A;
Magnetic Releases Operate: B Curve: Between 3 and 5 in;
C Curve: Between 5 and 10 in;
D Curve: Between 10 and 14 in;
Mechanical Life: 20000times;
Protection Degree: IP20;
Rated Current: 2A 6A 10A 16A 32A 63A;
Rated Frequency: 50/60Hz;
Time Delay: 1.13>1h Non-Trip;
Time Delay 1.45in: 1.45in<1h Trip;
Time Delay 2.55in: 1s<60s Trip;
Stardard: IEC898, CE, CB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN-Rail Mounting;
Structure: MCB;
Poles Number: 1,2,3,4,P;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Handle Colour: Optional Colour;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail;
Structure: MCB;
Poles Number: 1p,2p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 500V AC;
ICU: 10ka;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Structure: MCB;
Poles Number: 1p/2p/3p/4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Voltage Ui: 1000V;
Imp: 6ka/10ka;
Rated Current: 63A;
Tripping Curve: B/C;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: ACB;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB;
Electricity Type: Vacuum;
Number of Pole: 1;
Phase: 1/2/3;
Main Circuit Rating Voltage: 12KV;
Main Circuit Rating Current: 1600/2000A;
Name: Vacuum Interrupter;
Shelf life: 20years;
Color: Silver, Copper;
Afterserivce: Yes;
|