| Specification |
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Manual Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: MCB;
Poles Number: 1;
Type: Circuit Breaker;
Function: Circuit-Breaker Failure Protection;
Pole: Single;
Rated Voltage: AC230/400V;
Tripping Curve: B, C, D;
Rated Breaking Capacity: 6000A;
Magnetic Releases Operate: B Curve: Between 3 and 5 in;
C Curve: Between 5 and 10 in;
D Curve: Between 10 and 14 in;
Mechanical Life: 20000times;
Protection Degree: IP20;
Rated Current: 2A 6A 10A 16A 32A 63A;
Rated Frequency: 50/60Hz;
Time Delay: 1.13>1h Non-Trip;
Time Delay 1.45in: 1.45in<1h Trip;
Time Delay 2.55in: 1s<60s Trip;
Stardard: IEC898, Ce, CB;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Motor Protector;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Current: 1-1.6A;
AC Voltage: 690V;
Pole: 3pole;
Temperature: -5-+40;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vcb;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 12kv;
Rated Current: 630/1250A;
Mechanical Life: 10000times;
Rated Frequency: 50Hz or 60Hz;
|
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Fixed;
Structure: Vcb;
Poles Number: 3;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Voltage: 12kv;
Rated Current: 630/10A;
Mechanical Life: 10000times;
Rated Frequency: 50Hz or 60Hz;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: High-Speed Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: MCB;
Poles Number: 4;
Type: Voltage Protector;
Function: OVP(Overvoltage Protection);
Rated Operating Current: 1A-63A Adjustable (Default 63A);
Undervoltage Action Cut-off Value: 210V-145V(Default 170V);
Overvoltage Action Cut off Value: 230V-300V (Default 270V);
Limit Current Protection: Depends on Rated Current;
Power Delay After Power off: 30s (0-180s);
|