| Specification |
Type: High-voltage;
Structure: Double-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Number of Poles: Three Pole;
Grounding: Double Ground;
Series: Three;
Run: Turn the Horizontal;
Switching Mode: Double-Throw Type;
Common Model: YR;
Structure of Operating: Electric;
Breaking Capacity: High;
Usage: High Voltage;
Shape: Circle;
Fusing Speed: FF;
Fusing Device: Discoloration;
Standard: JIS;
Type: Switch;
Impulse Withstand Voltage: 95/195 Kv;
Power-Frequency Withstand Voltage: 42/80kv;
Material: Porcelain;
Technical Standard: IEC60694, IEC62271-102 Lafest Standard;
|
Type: Low-voltage;
Structure: Single-column Disconnector;
Installation: Indoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Plug-in Type;
Number of Poles: Three Pole;
Grounding: Single Ground;
Series: Three;
Run: Vertical Rotation;
Switching Mode: Single Throw-in;
Common Model: YR;
Structure of Operating: Electric;
Voltage Ui: 1000V;
Rated Voltage: 800A;
Knob Lock: with Lock;
Pole Array: 02, 11, 03, 12, 04, 22, 20, 21, 30, 40;
Installation Method: Directly Operate The Handle in The Cabinet;
Wiring: Switch Is Non-Polarized;
Ambient Temperature: -40°c to +70°c;
Side Mount: PE Pole;
Side Mount Auxiliary Contac: P1: 1no+1nc P2: 2no P3:1no;
High Temperature Withstand: No Derating up to 70°c;
Phase Barrie: Pb315 for Eha-315, Pb630 for Eha-630;
Terminal Shield: Ts315 for Eha-315, Ts630 for Eha-63;
Extension Rod: Er0620/Er1020,0620 Represents Square Rod Size 6, L;
Location: 03 3p with Lock;
Frame: 630;
|
Type: High-voltage;
Structure: Three-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Number of Poles: Three Pole;
Series: Three;
Common Model: Lbs;
Structure of Operating: Electric;
Brand: Dgg;
Rated Voltage: 12/24/36kv;
Rated Current: 630A/1250A;
Rated Frequency: 50/60Hz;
Rated Short-Circuit Breaking Current: 20ka;
|
Type: High-voltage;
Structure: Three-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Horizontal Rotary Type;
Number of Poles: Three Pole;
Structure of Operating: Electric;
Rated Frequency: 50;
Rated Voltage: 12;
Rated Current: 630;
Mechanical Life: 3000;
|
Type: High-voltage;
Structure: Double-column Disconnector;
Installation: Outdoor High-voltage;
Operation: Electric;
Grounding Mode: Grounding;
Movement Mode: Vertical Rotary Type;
Common Model: Dgw11-15;
Structure of Operating: Electric;
Brand: Dgg;
Rated Voltage: 12kv;
Rated Frequency: 50Hz;
Rated Current: 400/1250/2000/2500A;
|