| Specification |
After-sales Service: World-Wide;
Application: Laboratory Apparatus;
Warranty: > 1Year;
Detection Method: Spectrograph;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Prism Spectrometer;
Light Number: Polychromator;
X-ray Tube Type: American Varian Side-Window and End-Window;
Target Material: Rh or AG;
Parameter Settings: Integrated Adjustable Filament Power Supply, Volta;
M Method: Robotic Arm Full Intelligent Automatic Sampling Sy;
Excitation Source: Low Ripple , High Stability;
Voltage: 0-50kv Continuously Adjustable;
Power: 100W;
Quantity: Sample Placement Range 0-36;
Weight: 150kg (Net Weight), 200kg (Gross Weight);
Environmental Requirement: T 5℃-30℃ H 20%-80%;
|
After-sales Service: Lifelong;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Interferometer: Cube-Corner Michelson Interferometer;
Beam Splitter: Cube-Corner Michelson Interferometer;
IR Source: High Intensity, Long Lifetime, Air-Cooled IR Sourc;
Wavenumber Range: 7800cm-1~350cm-1;
Wavenumber Accuracy: ±0.01 Cm-1;
Scanning Speed: Microprocessor Control, Different Scanning Speed S;
Communication: Ethernet Interface (Standard);
Data Output: Standard Data Format, Report Generation and Output;
|
After-sales Service: Lifelong;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Interferometer: Cube-Corner Michelson Interferometer;
Beam Splitter: Cube-Corner Michelson Interferometer;
IR Source: High Intensity, Long Lifetime, Air-Cooled IR Sourc;
Wavenumber Range: 7800cm-1~350cm-1;
Wavenumber Accuracy: ±0.01 Cm-1;
Scanning Speed: Microprocessor Control, Different Scanning Speed S;
Communication: Ethernet Interface (Standard);
Data Output: Standard Data Format, Report Generation and Output;
|
After-sales Service: Lifelong;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Infrared;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Polychromator;
Customized: Customized;
Sample Forms: Small Particle, Powder, Paste, Liquid, Plate Sampl;
Wavelength Accuracy: 950-1650nm;
S/N Ratio: 10000:1 @Average of 128 Times;
Wavelength Repeatability: <1nm;
Light Absorbance Repeatability: <0.0003au;
Light Source: Tungsten Halogen Lamp, Life Span 1000h;
Light Spot Diameter: 25mm;
Sample Cup Volume: 300ml;
|
After-sales Service: Lifelong;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Infrared;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Interferometer Spectrometer;
Light Number: Polychromator;
Customized: Customized;
Sample Forms: Small Particle, Powder, Paste, Liquid, Plate Sampl;
Wavelength Accuracy: 950-1650nm;
S/N Ratio: 10000:1 @Average of 128 Times;
Wavelength Repeatability: <1nm;
Light Absorbance Repeatability: <0.0003au;
Light Source: Tungsten Halogen Lamp, Life Span 1000h;
Light Spot Diameter: 25mm;
Sample Cup Volume: 300ml;
|