| Specification |
Type: Wireless Alarm Host;
Function: Networked;
Usage: Door, Auto, Personal, Window, Fire, Smoke;
Alarm Volume (within 1m): ≥110dB;
Networking Mode: GSM Dial-up;
Receive Frequency: 433.92MHz;
Wiring Mode: Sub-Line System;
Color: Black;
Wireless Sensors: 99;
Wired Sensors: 4;
Product's Name: Burglar GSM Alarm System Wireless;
Delivery Port: Shenzhen;
Technology: Infrared;
Factory Since: 1998;
OEM/ODM Service: Availably;
Gift Box Dimension: 32cm*26.5cm*6.2cm(L*W*H) 1.5kg;
|
Type: Fire Alarm Host;
Function: Linkage;
Usage: Auto, Fire, Smoke;
Networking Mode: Linkage;
Receive Frequency: 50Hz;
Wiring Mode: Bus System;
Approvals: Lpcb / Ce-CPR;
No. of Loop: 1, 2, 4, 6 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 230VAC+10%-15%, 50Hz;
Indicator: 24 LED Status/160 Zone Indicators;
Network Panel to Panel: 512 Panels-Single Ring [Ideal];
Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 4 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 2 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Receive Frequency: 50Hz;
Wiring Mode: Bus System;
Approvals: Lpcb / Ce-CPR;
No. of Loop: 1, 2, 4, 6 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 230VAC+10%-15%, 50Hz;
Indicator: 24 LED Status/160 Zone Indicators;
Network Panel to Panel: 512 Panels-Single Ring [Ideal];
Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 4 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 2 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Receive Frequency: 50Hz;
Wiring Mode: Bus System;
Approvals: Lpcb / Ce-CPR;
No. of Loop: 1, 2, 4, 6 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 230VAC+10%-15%, 50Hz;
Indicator: 24 LED Status/160 Zone Indicators;
Network Panel to Panel: 512 Panels-Single Ring [Ideal];
Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 4 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 2 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Wiring Mode: Bus System;
Approvals: Lpcb / Ce-CPR;
No. of Loop: 1 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 100-240VAC+10%-15%, 50/60Hz;
Indicator: 24 LED Status/30 Zone Indicators;
Network Panel to Panel: 128 Panels-Single Can Bu(Loop);
System Capacity Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 2 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 1 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|