| Specification |
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: AC Resonant Test System;
Accuracy Grade: RMS 1.5;
Display: Digital;
Control: Controller or Computer;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
Max Test Voltage: up to 10000kv or Higher;
Max Capacity: up 10000kVA or Higher;
Product Name: AC Resonant Test System;
Calibration: Support Calibration;
|
After-sales Service: Long Life Support;
Warranty: One Year or Extend;
Type: Partial Discharge Test Equipment;
Accuracy Grade: 1.5 or Customized;
Display: Digital;
Control: Manual and Automatic;
Weight: Customized;
Power Source: AC380V;
Output Voltage: 0~1200kv;
Pd Under Rated Volt(PC)(250-600): <3PC;
Temp Rising (60mins at Rated Current): <50K(Power Frequency);
Output Current: 0~10A;
Product Name: Partial Discharge Test Equipment;
Pd Level: 5PC;
Insulating Medium Material: Oil or Gas;
Console: Auto and Manual;
Duty Time: 1 Min or Customize;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Capacitive Load;
Display: LCD;
Control: Computer Control;
Weight: 5kgs;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Language: English;
Model: Vlf Hipot Tester with Tan Delta Measuring;
Input Voltage: 220V or 120V;
Frequency: 50Hz/60Hz;
Function1: Vlf Hipot,AC Hipot,DC Hipot, Tan Delat Measuring;
Function 2: Partial Discharge Detect;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Vlf Hipot Tester;
Accuracy Grade: 0.5;
Load Way: Electronic Load;
Loading Method: Capacitive Load;
Display: LCD;
Control: Computer Control;
Weight: 5kgs;
Power Source: AC220V;
Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz;
Stability of Frequency: Fluctuation < 0.5%;
Measurement Accuracy: +-3%;
Positive and Negative Voltage Peak Error: <=3%;
Voltage Waveform Distortion: <=5%;
Product Name: Vlf Hipot Tester;
Test Voltage Range: 30kv/40kv/50kv/60kv/70kv/80kv;
Standard: IEC;
Language: English;
Model: Vlf Hipot Tester with Tan Delta Measuring;
Input Voltage: 220V or 120V;
Frequency: 50Hz/60Hz;
Function1: Vlf Hipot,AC Hipot,DC Hipot, Tan Delat Measuring;
Function 2: Partial Discharge Detect;
|
After-sales Service: Support;
Warranty: One Year and Can Be Extended;
Flow: 2000L/H;
Model: Hmzyd-;
Stage: 2;
Working Vacuum: 60PA;
Limit Vacuity: 3 PA;
Working Pressure: ≤0.5MPa;
Electric Heating Power: 15 Kw;
General Power: 18kw;
Inlet (Outlet) Diameter: φ42;
Continuous Working Time: ≥600h;
Time to Failure: ≥8000h;
Working Noise: ≤75dB;
Lift Suction: 30m;
|