| Specification |
Classification: Automated Sample Processing System;
Type: Automated Sample Processing System;
Group: All;
Throughput: 1~48;
Processing Time: 48 Samples/16min;
Sample Type: Plasma, Serum, Whole Blood, Swab Solution and Othe;
Sample Rack: Sample Rack;
Robot Arm: 2PCS(Dispensation Arm and Screw Cap Arm);
Plate Position: 3PCS(Compatible with Multi-Specification Deep-Well;
Tip Position: 3PCS(Including Tip Waste Box Position);
Reagent Rack: 1PC(4*2ml Centrifuge Tube+4*2ml Freezing Tube+4*5m;
Protective Function: Can Be Used in a Biological Safety Cabinet;
Liquid Detection: Pneumatic Liquid Level Detection Principle, Intell;
Pipetting Volume: 5~1000μL(1000/50μL Tip);
Pipetting Accuracy: 10μL, CV≤1.5%, Accuracy≤6.0%, 50μL Tip;
Power Supply: 220V, 50/60Hz; 110V, 60Hz;
After-Sale: Online;
Warranty: One Year;
|
Classification: Hematology Analyzer Reagent;
Type: Orphee Mythic Lyse;
Group: All;
Instrument Classific: Class II;
Expiry Date: 2 Years;
Sample: Free;
Packing: 16PCS/CTN;
|
Classification: Imaging Diagnostic Equipment;
Brand Name: Forermed;
Model Number: Kx-410;
Power Source: Electric;
Shelf Life: 1year;
Quality Certification: CE;
Instrument Classification: Class II;
Safety Standard: En 149 -2001+A1-2009;
Product Name: Xray Film Printer;
Print Technology: Direct Thermal (Dry, Daylight-Load Film);
Spatial Resolution: 320dpi (12.6 Pixels/mm);
Throughput: 14*17",50sheets/H;8*10" ^70 Sheets/H;
Grayscale Contrast Resolution: 14 Bits;
Film Transferring Method: Rubbing;
Film Tray: Two Supply Tray, 200-Sheet Capacity Total;
Film Sizes: 8%1o",10"X12",14nx17n;
|
Classification: ICU;
Type: Anesthesia Machine;
2-Tubes Flowmeters: O2 & N2o; 0.1L/Min ~ 10L / Min;;
Oxygen Flush: 25~75 L / Min;
Respiration Mode: A/C, Ippv, Sippv, Manual;
Tidal Volume: 50~1500ml;
I/E Ratio: 1:1.5 ~ 1:3.0;
One Vaporizers: Enflurane/ Isoflurane/Sevoflurane/Halothane;
Vaporizer Setting Range: 0.5%~5%;
Respiration Frequency: 4~40 Bpm;
Ptr: -1.0kpa ~ 1.0 Kpa;
CO2 Absorber Capacity: 1 Kg;
Optional: Patient Monitor;
Display: LED Display;
Ventilation Mode: A/C,Ippv,Sippv,Manual;
Back-up Power Supply: at Least 4 Hours;
Respiratory Rate: 4-40bpm;
|
Classification: Imaging Diagnostic Equipment;
Type: X Ray Equipment;
Group: Female;
Operation: Multiple Function and Easy Operation;
Maximum Output Power: 5kw;
Output Current Range: 10 ~ 160 Ma;
RAM Capacity: 8g;
Anode Heat Capacity: 300khu;
Properties: Medical X-ray Equipments & Accessories;
Output Voltage Range: 20 ~ 40 Kv;
C Arm Rotation Range: -155°~ +195°;
Vertical Movement Range of C-Arm: 630mm-1440mm;
|