| Specification |
After-sales Service: Repair Service and Free Parts Replacement;
Warranty: 1.5years;
Display: LCD;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Portable;
Type: Cod Analyzer;
Product Name: Cod Analyzer;
Model: Cod-100;
Measuring Principle: Dichromate Colorimetric Method;
Cod: (0~150)Mg/L, (0~1500)Mg/L;
Basic Accuracy: ±8%;
Repeatability: ≤3%;
Stability: Cod Data Changing Less Than 6mg/L Within 20mins;
Calibration: Two-Point Calibration(Zero and Full Scalecalibrati;
Data Storage: 200 Data with Time-and-Date Stamp;
Digestion Method: Sealing Reflux Method(Could Dispelling 21 Samples;
Digestion Temperature: 100~165°C;
Digestion Time: 0~120min;
Power Supply: AC110/220V±10%, 50/60Hz;
Standard Accessory: Cod-100r Digester;
Package Size(W*D*H): Cod-100: 370*305*330mm, Digester: 575*435*285mm;
|
After-sales Service: 12 Months;
Warranty: 12 Months;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Cod;
Measurement Method: Diphenylcarbazide Spectrophotometry;
Measuring Range: 0-2/5/8mg/L; Expandable;
Measuring Cycle: Configurable;
Lower Limit of Quantification: ≤0.01mg/L;
Indication Error: ±5%;
Precision: ≤5%;
Zero Drift: ±5%;
Range Drift: ≤5%;
Digital Input: 2 Channel Switch;
Analog Output: 1 Channel 4~20mA;
Digital Communications: RS232 / RS485;
Operating Temperature: 5℃~40℃;
Power Supply: AC 100-240V; 50/60Hz;
Power: 80W;
Size: 800mm X 400mm X 330mm;
|
After-sales Service: 12 Months;
Warranty: 12 Months;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Cod;
Measurement Method: O-Phenanthroline Spectrophotometry;
Measuring Range: 0-2/4/8mg/L; Expandable;
Measuring Cycle: Configurable;
Lower Limit of Quantification: ≤0.025mg/L;
Indication Error: ±10%;
Repeatability: ≤5%;
Zero Drift: ±5%;
Range Drift: ≤10%;
Digital Input: 2 Channel Switch;
Analog Output: 1 Channel 4~20mA;
Digital Communications: RS232 / RS485;
Operating Temperature: 5℃~40℃;
Power Supply: AC 100-240V; 50/60Hz;
Power: 80W;
Size: 800mm X 400mm X 330mm;
|
After-sales Service: 12 Months;
Warranty: 12 Months;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Cod;
Measurement Method: Zinc Reagent Spectrophotometry;
Measuring Range: 0-2/5/10mg/L; Expandable;
Measuring Cycle: Configurable;
Lower Limit of Quantification: ≤0.05mg/L;
Indication Error: ±5%;
Precision: ≤5%;
Zero Drift: ≤5%;
Range Drift: ≤5%;
Digital Input: 2 Channel Switch;
Analog Output: 1 Channel 4~20mA;
Digital Communications: RS232 / RS485;
Operating Temperature: 5℃~40℃;
Power Supply: AC 100-240V; 50/60Hz;
Power: 80W;
Size: 800mm X 400mm X 330mm;
|
After-sales Service: 12 Months;
Warranty: 12 Months;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Type: Cod;
Measurement Method: Isonicotinoic Acid Barbituric Acid Spectrophotome;
Measuring Range: 0-0.5/1/2mg/L; Expandable;
Measuring Cycle: Configurable;
Lower Limit of Quantification: ≤0.04mg/L;
Indication Error: ±10%;
Repeatability: ≤5%;
Zero Drift: ≤5%;
Range Drift: ≤5%;
Digital Input: 2 Channel Switch;
Analog Output: 1 Channel 4~20mA;
Digital Communications: RS232 / RS485;
Operating Temperature: 5℃~40℃;
Power Supply: AC 100-240V; 50/60Hz;
Power: 80W;
Size: 800mm X 400mm X 330mm;
|