| Specification |
Breaking Capacity: High Voltage Circuit Breakers;
Operation: Energy-storage Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Vacuum;
Installation: Single-Rod/Double-Rod Installation;
Structure: Pole Type;
Poles Number: /;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Voltage: 12 Kv;
Rated Current: 630 a;
Power Consumption: Total Power Consumption≤3W;
Communication Protocol: Dl/T634.5101, Dl/T634.5104;
Rated Short-Circuit Breaking Current: 20 Ka;
Mechanical Life: 10000 Times (Operations);
Backup Power Supply: Battery and Super Capacitor;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail 35mm;
Structure: MCB;
Poles Number: 1, 2, 3, 4;
Type: Isolating;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Current in: 20,32,40,63,80,100,125;
Poles: 1, 2, 3, 4;
Rated Voltage Ue: 230/400V;
Rated Breaking Capacity: 6000;
Terminal Connection Type: Cable/Pin-Type Busbar;
Mechanical Life: 8500;
Electrical Life: 1500;
Protection Degree: IP20;
Wiring Method: From Top or Bottom;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: DIN Rail 35mm;
Structure: MCB;
Poles Number: 1, 2, 3, 4;
Type: Isolating;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection);
Rated Current in: 20,32,40,63,80,100,125;
Poles: 1, 2, 3, 4;
Rated Voltage Ue: 230/400V;
Rated Breaking Capacity: 6000;
Terminal Connection Type: Cable/Pin-Type Busbar;
Mechanical Life: 8500;
Electrical Life: 1500;
Protection Degree: IP20;
Wiring Method: From Top or Bottom;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Structure: MCB;
Type: Circuit Breaker;
Surface Treatment: Nylon;
|
Breaking Capacity: Low Voltage Circuit Breakers;
Operation: Electric Type;
Speed: Normal Type Circuit Breaker;
Arc-extinguishing Medium: Air;
Installation: Fixed;
Structure: Moulded Case Circuit Breaker;
Poles Number: 3p 4p;
Type: Circuit Breaker;
Function: Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection;
Rated Working Current: 16A to 1600A;
Production Standard: IEC60947-2;GB14048.2;
Rated Working Voltage: 690V and Below;
Adjustable: Electric;
|