| Specification |
After-sales Service: Yes;
Warranty: 1 Years;
Type: Strength Testing Machine;
Maxcapacity: 500W;
Accuracy Grade: 0.5;
Load Way: Mechanical Load;
Loading Method: Static Load;
Display: Digital;
Control: Manual Control;
Weight: 0-100Kg;
Power Source: AC220V;
Oil Cylinder Position: Top;
Power: Electronic;
Repeatability: 0.5%;
Usage: Auto Testing Machine;
Principle: Pensky-Martens;
Supply Voltage: AC220V±10%;
Flash Fire Sensor: Ion Detection Ring;
Asphalt Flash Point Tester: Transformer Oil Tester;
Testing Range: Indoor Temperature-400oc;
Temperature Sensor: Platinum Resistance(PT100);
Working Humidity: <85%;
|
After-sales Service: 2 Years;
Warranty: 2 Years;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Type: Sulfur-in-Oil Analyzer;
Maxcapacity: <1000KN;
Accuracy Grade: 1;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 13 Kg;
Power Source: AC220V;
Oil Cylinder Position: Top;
Sample Measurement: Automatic Measurement;
The Fastest Measurement Time: 1 Minute;
Measurement Repeat Times: 1, 2, 3, 5, 10(Times);
Feature: Rapid and Accurate;
Detection Limit: 17 Ppm;
Calibration Curve Numbers: It Can Save 10 Calibration Curves;
Default Measurement Time: 3 Minutes;
Measuring Range: 0.0017%~5%;
Oil Sample Quantity: 3 Ml-5ml;
Test Standard: ASTM D4294;
Measurement Time: It Can Preset 30, 60, 90, 120, 150s;
|
After-sales Service: 2 Years;
Warranty: 2 Years;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Type: Universal Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Mechanical Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: AC220V;
Oil Cylinder Position: Under;
Sulfur in Fuel: ASTM D4294;
Measurement Time: It Can Preset 30, 60, 90, 120, 150s;
Measuring Range: 0.0017%~5%;
Measurement Repeat Times: 1, 2, 3, 5, 10(Times);
Detection Limit: 17 Ppm;
Oil Sample Quantity: 3 Ml-5ml;
Sample Measurement: Automatic Measurement;
Default Measurement Time: 3 Minutes;
Calibration Curve Numbers: It Can Save 10 Calibration Curves;
The Fastest Measurement Time: 1 Minute;
|
After-sales Service: 2 Years;
Warranty: 2 Years;
Max Diameter of Workpiece: <500mm;
Mass Scope of Workpiece: <900kg;
Type: Universal Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 0.5;
Load Way: Mechanical Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: AC220V;
Oil Cylinder Position: Under;
D5453 Sulfur Analyzer: ASTM D5453 Total Sulfur Analyzer;
Applications: Engine Fuels, Engine Oil;
Viscosities of Samples: 0.2~20 Cst (mm2/S) at Room Temperature;
Boiling Range of Samples: Approximately 25c to 400c;
Sample Types: Liquid Hydrocarbons;
Measuring Range: (0.2~8000)Mg/L;
ASTM D5453 Sulfur Content: Sulfur in Fuels Tester by ASTM D5453;
Total Sulfur Content Analyzer: Total Sulfur by Uvf According to ASTM D5453;
|
After-sales Service: 2 Years;
Warranty: 2 Years;
Max Diameter of Workpiece: 900mm;
Mass Scope of Workpiece: <900kg;
Type: Universal Testing Machine;
Maxcapacity: <1000KN;
Accuracy Grade: 1;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: 0-100Kg;
Power Source: AC220V;
Method of Determination: Ultraviolet Fluorescence Method (S);
Dimension: Host: 305(W)*460(D)*440(H)mm;
Applications: Engine Fuels, Engine Oil;
Gas Source Requirements: High-Purity Argon: Above 99.9% High Purity Oxygen:;
All Weight: Host: 20kg; Temp Controller: 40kg;
Boiling Range of Samples: Approximately 25c to 400c;
Temperature Range: Room Temp~1300centigrade;
Measuring Range: 0.1~10000mg/L (High Concentration Should Be Dilute;
Sample Injection Quantity: Solid: 1-90mg;
Power Supply: AC220V+-22V, 50Hz+-0.5Hz, 1500 W;
Sample Types: Solid, Gas and Liquid;
|