| Specification |
After-sales Service: Yes;
Warranty: 1 Year;
Type: Automatic Potentiometric Titrator;
Analysis Method: Chemical Analysis;
Display: Digital;
Application: Chemicals;
Portable: Portable;
Physical Analysis Type: Automatic Potentiometric Titrator;
Chemical Analysis Type: Automatic Potentiometric Titrator;
Operating Mode: Touch Screen;
Heating Mode: Automatic Potentiometric Titrator;
Off Mode: Automatic;
Test Range: 0.002 ~ 1mg KOH / G;
Power: 500W;
Huminity: ≤85% Rh;
Power Supply: AC220V / 50Hz;
Repeatability: ≤0.005mg KOH / G;
Measurment Error: ≤ ± 0.005mg KOH / G;
Measurement Error: ≤ ± 0.005mg KOH / G;
Standards: GB/T7599-87, GB/T264-83, GB/T28522-2002;
Aftersales Service: Yes;
|
After-sales Service: 1 Year;
Warranty: 1 Year;
Type: Moisture Meters;
Analysis Method: Other;
Display: LED;
Application: Moisture Meters;
Portable: Portable;
Physical Analysis Type: Weightlessness Method;
Chemical Analysis Type: Other;
Operating Mode: Keyboard;
Heating Mode: Other;
Off Mode: Time-Lapse;
Measuring Object: Grain;
Measuring Moisture Range: 3-35%;
Repeating Error: 0.2%;
Measuring Error: 0.5%;
Working Power: 4PCS *1.5V AA Batteries;
Working Temperature: 0-40℃;
Net Weight: 850g;
Auto Power-off: 3 Minutes Shut Down Automatically;
|
After-sales Service: Yes;
Warranty: 1 year;
Type: Oil-Water Moisture Meter;
Analysis Method: Physical Analysis;
Display: ExtraLCD;
Application: Test and Measurement Instruments;
Portable: Portable;
Chemical Analysis Type: Karl Fischer Method;
Operating Mode: Touch Screen;
Heating Mode: Step Heating;
Off Mode: Manual;
Electrolyte Water Content Resolution: 10ug~1000ug ± 3ug;
Measurement Range: 0ug-100mg;
Resolution: 0.1ug;
Electrolyzing Current: 0~400mA;
Max Electrolyzing Speed: 2.4mg/M;
Voltage Source: AC220V± 20%;
Max Power Consumption: 30W;
|
After-sales Service: Online Support Through Email, Telephone, Whatsapp;
Warranty: 1 Year;
Type: Oil-Water Moisture Meter;
Analysis Method: Chemical Analysis;
Display: ExtraLCD;
Application: Petroleum, Chemical Engineering, Pharmacy, Electri;
Portable: Non-portable;
Chemical Analysis Type: Karl Fischer Method;
Operating Mode: Touch Screen;
Off Mode: Manual;
Standard: ASTM D1533, D6304, D1744;
Function: Analyze The Moisture Content in Petroleum Products;
Electrolysis Current: 0-400 Ma Automatic Control;
Measurement Range: 0.01ug Water - 200mg Water;
Sensitivity: 0.01ug Water;
|
After-sales Service: Online Support Through Email, Telephone, Whatsapp;
Warranty: 1 Year;
Type: Dew Point of Moisture Meter;
Display: ExtraLCD;
Application: Petroleum, Chemical Engineering, Pharmacy, Electri;
Portable: Portable;
Chemical Analysis Type: Toluene Method;
Operating Mode: Touch Screen;
Off Mode: Manual;
Function: Measure The Inert Gas in The Gas Chamber of The EQ;
Dew Point Range: -80 ℃~+20 ℃;
|