| Specification |
After-sales Service: 1 Year;
Warranty: 1 Year;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Non Portable;
Use: Measurement of Sludge Concentration;
Mounting Type: Immersion Type Installation;
Theory: Principle of Scattered Light;
Voltage - Supply: 12~24VDC;
Operating Temperature: 5~50℃;
Resolution: 0.001g/L;
|
After-sales Service: Yes;
Warranty: 1year;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Portable;
Type: Turbidity Meter;
Product Name: Portable Turbidimeter Turbidity Meter;
Measuring Range: (0~20.00) Ntu, (20.0~200.0) Ntu,(200~1000) Ntu;
Resolution: 0.01ntu, 0.1ntu, 1ntu;
Accuracy: +-2% of Reading+0.02ntu;
Repeatability: ≤0.5%;
Fluctuation: ±0.5% Fs/30min;
Light Source: 850nm LED;
Meet Standard: ISO 7027;
Selectable Turbidity Units: Ntu, Fnu and Ebc;
Waterproof: IP65;
Calibration Points: 1-3 Points;
Autoranging: 0-200 Ntu;
Turbidity Bottles Included: 5PCS;
Carrying Case: Included;
Brand: Aoda;
|
After-sales Service: Yes;
Warranty: 1year;
Display: Digital;
Appliance: Food Analysis, Medical Research, Biochemistry;
Portable: Portable;
Type: Conductivity Meter;
Product Name: Conductivity Ec TDS Meter;
Test Parameters: Ec/Temp.(TDS);
Conductivity Range: 0.00μS/Cm~200.0 Ms/Cm;
Resolution: 0.01μS/Cm Minimum, Changed with Range;
Accuracy: ±1.0% Fs;
Reference Temperature: 25℃;
Calibration Points: 1;
Standard Recognition: 84μS/Cm, 1413μS/Cm, 12.88ms/Cm;
TDS Range: 0.00mg/L~100.0g/L;
Reading Mode: Auto Read, Continuous;
Temp. Compensation: Atc, Mtc;
Data Storage: 200 Results Each;
IP Rating: IP65;
Power: Rechargeable Lithium Battery, AC Adapter(Input:100;
Net Weight: 400g;
|
After-sales Service: Online Helps, Installation Helps, etc.;
Warranty: 1year;
Portable: Portable;
Light Source: Semiconductor Laser;
Flow Rate Range: 20-60ml/Min;
on-Site Testing Pressure: 0.1-0.6MPa;
Particle Size Range: 1-500um;
Interface: USB Interface, Power Interface;
Data Storage: 1000 Groups and Support U Disk;
Limit Coincidence Error: 40000 Particles/Ml;
Counting Volume: 1-999ml;
Test Interval: 1 Second-24 Hours;
Reference Value of Water Activity: 0-1aw;
Water Content: 0-300ppm;
|
After-sales Service: Online Helps, Installation Helps and Training;
Warranty: 1year;
Portable: Non Portable;
Testing Standard: ASTM D5800, Sh/T0059;
Testing Method: Noack Method;
Pressure Regulation: High Precision Needle Valve;
Suction Method: Vacuum Pump;
Temperature Control Mode: Digital Display Pid Temperature Control;
|