| Specification |
Type: Smoke Detectors;
Anti-theft Alarm System Approach: Conventional;
Anti-Theft Alarm System Type: Smoke Alarms;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Operating Voltage Range: 18V-28VDC;
Work Current: Less Than 2.5mA;
Smoke Sensitivity: 0.2-0.3 dB/M;
Standard Number Ref: En 57-7:2000;
Standby Current: 120ua@24VDC;
Maximum Alarm Current: 15mA@24VDC;
Ec Certificate: 0832-CPR-F2071;
|
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: 4 Wire Smoke Detector;
Operating Voltage: 9-35VDC;
Standby Current: 55 uA-13 mA;
Alarm Current: 20 mA-60 mA;
Indicator: Two LEDs;
Wiring: 4 Wires;
Standard: EN54-7;
Output: Relay Dry Contact;
Accessory: Dust Proof Cover;
Material: Plastic Housing and Metal Parts;
Dimention: About 103mm X 53mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detector, Fire Alarm System;
Application: Office, Factory, Warehouse, Apartment, Hotel, Bank;
|
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: 4 Wire Smoke Detector;
Operating Voltage: 9-35VDC;
Standby Current: 55 uA-13 mA;
Alarm Current: 20 mA-60 mA;
Indicator: Two LEDs;
Wiring: 4 Wires;
Standard: EN54-7;
Output: Relay Dry Contact;
Accessory: Dust Proof Cover;
Material: Plastic Housing and Metal Parts;
Dimention: About 103mm X 53mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detector, Fire Alarm System;
Application: Office, Factory, Warehouse, Apartment, Hotel, Bank;
|
Type: Temperature Sensor Probe;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Types of Smoke Detectors: Heat Detector;
Infrared Sensor Installation: Ceiling;
Product Name: Heat Alarm Detector;
Operating Voltage: 9V Battery;
Standby Current: ≤20uA;
Alarm Current: ≤50mA;
Indicator: Two LEDs;
Alarm Decibel: 85dB;
Alarm Temperature: 57℃;
Detecting Area: 20-40m²;
Test Button: Yes;
Wireless Output: Optional;
Dimention: 105mm X 55mm;
Operating Temperature: -10℃ to +50℃;
Operating Humidity: ≤95% RH;
Usage: Fire Detection, Heat Detection, Fire Alarm;
Application: Kitchen, Restaurant, Home, Office, Apartment etc.;
|
Type: Temperature Sensor Probe;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Fixed Temperature;
Infrared Sensor Installation: Ceiling;
Product Name: Conventional Heat Detector;
Operating Voltage: 9-36VDC;
Standby Current: ≤50uA;
Alarm Current: ≤50mA;
Indicator: Two LEDs;
Wiring: 2 Wires;
Standard: EN54-5;
Output: Remote LED Indicator;
Accessory: Dust Proof Cover;
Material: Plastic Housing and Metal Parts;
Dimention: About 100mm X 57mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Heat Detection, Fire Alarm System;
Application: Home, Kitchen, Boiler Room, Generator Room etc.;
|