| Specification |
Type: Smoke Detectors;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Installation: Ceiling;
Product Name: Factory Direct Sales High Sensitivity Smoke Detect;
Operating Voltage: 9-28VDC;
Standby Current: ≤60ua;
Alarm Current: ≤30mA;
Indicator: Two LEDs;
Wiring: 2 Wires;
Standard: En54-7;
Output: Remote LED Indicator;
Accessory: Dust Proof Cover;
Material: Plastic Housing and Metal Parts;
Dimention: About 100mm X 50mm;
Operating Temperature: -10 to +55 Celsius Degree;
Operating Humidity: ≤95% No Condensing;
Usage: Fire Detection, Smoke Detector, Fire Alarm System;
Application: Office, Factory, Warehouse, Apartment, Hotel, Bank;
|
Type: Smoke Sensor Probe;
Anti-theft Alarm System Approach: Active;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Anti-Theft Alarm System Distance: Common Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Probe Type: Infrared Temperature Sensor;
Infrared Sensor Installation: Embedded Wall;
Combustible Gas Detector Model: None;
Power: 9VDC Battery;
Alarm Indicator: Flash LED Power Indicator;
Work Temperature: -10°C-50°C;
Alarm Spl: ≥85dB(1m );
Technology: SMT Adopted,High Accuracy Temperature Sensor;
|
Type: Smoke Sensor Probe;
Anti-theft Alarm System Approach: Active;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Anti-Theft Alarm System Distance: Common Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Probe Type: None;
Infrared Sensor Installation: Embedded Wall;
Combustible Gas Detector Model: None;
Dual Power: DC9V Battery or AC110V/220V;
Alarm Indicator: Flash LED Power Indicator;
Work Temperature: -10°C-50°C;
Alarm Spl: ≥85dB(1m );
Technology: SMT Adopted,High Accuracy Temperature Sensor;
|
Type: Smoke Sensor Probe;
Anti-theft Alarm System Approach: Active;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Anti-Theft Alarm System Distance: Common Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Probe Type: None;
Infrared Sensor Installation: Embedded Wall;
Combustible Gas Detector Model: None;
Power: 9VDC Battery;
Alarm Indicator: Flash LED Power Indicator;
Work Temperature: -10°C-50°C;
Alarm Spl: ≥85dB(1m );
Technology: SMT Adopted,High Accuracy Temperature Sensor;
|
Type: Gas Sensor Probe;
Anti-theft Alarm System Approach: Active;
Anti-Theft Alarm System Type: Sound and Light Alarm;
Anti-Theft Alarm System-Wide: Wire Alarm Detectors;
Anti-Theft Alarm System Distance: Common Detectors;
Types of Smoke Detectors: Photoelectric Smoke Style;
Infrared Sensor Probe Type: None;
Infrared Sensor Installation: Embedded Wall;
Combustible Gas Detector Model: None;
Power: DC9V Battery;
Alarm Indicator: Flash LED Power Indicator;
Work Temperature: -10°C-50°C;
Alarm Spl: ≥85dB(1m );
Technology: SMT Adopted,High Accuracy Temperature Sensor;
|