| Specification |
Shell Material: Al-Zn Coated Steel/Cold-Rolled Steel;
Voltage Level: Low Voltage;
Installation: Fixed;
Structure: Withdrawable;
Current: AC;
Product Name: Low Voltage Withdrawable Switchgear;
Keywords: Switchgear;
Material: Copper Busbar, Al-Zn Coated Steel;
Feature: Modular Design, Withdrawable Units;
Application: Power Distribution, Motor Control;
OEM Custom: Yes;
ODM Custom: Yes;
Package: Export Standard Wooden Case;
|
Shell Material: Steel Plate;
Voltage Level: High Voltage;
Installation: Fixed;
Structure: Cabinet;
Current: AC;
Altitude: 1000m;
Ambient Air Temperature: 40°C Max, -15°C Min.;
Rated Frequency: 50Hz;
Current Rating: 630A/1250A/1300A;
Rated Peak Withstand Current: 50ka\63ka\80ka;
Product Model: Kyn61-40.5;
Main Busbar: 630A/1250A/1300A;
Equipped with a Circuit Breaker: 630A/1250A/1300A;
1min Power Frequency Tolerance: 95/110kv;
Lightning Shock Resistance: 185/215kv;
Auxiliary, Control Loop Tolerance: 2000V/1min;
Product Name: Armor Removed Test AC Metal-Enclosed Switchgear;
|
Shell Material: Steel Plate;
Voltage Level: High Voltage;
Installation: Fixed;
Structure: Cabinet;
Current: AC;
Altitude: 1000m;
Ambient Air Temperature: 40°C Max, -15°C Min.;
Rated Frequency: 50Hz;
Current Rating: 630A/1250A/1300A;
Rated Peak Withstand Current: 50ka\63ka\80ka;
Rated Voltage: 40.5 Kv;
Main Busbar: 630A/1250A/1300A;
Equipped with a Circuit Breaker: 630A/1250A/1300A;
1min Power Frequency Tolerance: 95/110kv;
Lightning Shock Resistance: 185/215kv;
Auxiliary, Control Loop Tolerance: 2000V/1min;
Rated Short-Time Withstand Current/Rated: 20ka/4s,25ka/4s,31.5ka/4s;
Rated Short-Circuit Interrupting Current: 20ka,25ka,31.5ka;
Rated Short-Circuit Closing Current: 50ka,63ka,80ka;
Rated Voltage of The Control Loop: DC:110V,220V,AC:110V,220V;
|
Shell Material: Steel Plate;
Voltage Level: High Voltage;
Installation: Fixed;
Structure: Cabinet;
Current: AC;
Altitude: 1000m;
Ambient Air Temperature: 40°C Max, -15°C Min.;
Rated Frequency: 50Hz;
Current Rating: 630A/1250A/1300A;
Rated Peak Withstand Current: 50ka\63ka\80ka;
|
Shell Material: Steel Plate;
Voltage Level: Low Voltage;
Installation: Fixed;
Structure: Cabinet;
Current: AC;
Ingress Protection: IP40;
Altitude: 2000mm;
Ambient Air Temperature: 40°C Max, -50°C Min.;
Rated Frequency: 50Hz;
Rated Operating Voltage: 380/660;
Power Frequency Withstand Voltage 1 Minu: 2500;
Product Name: Gck Low-Voltage Drawer-Type Switchgear;
Cabinet Structure: Drawer-Type Enclosure Structure;
Application Scenarios: Data Center Power Distribution;
Functional Characteristics: Modular Drawer Units;
Technical Parameters: Rated Operating Voltage;
Insulation Mode: Air Insulation;
Scenarios 1: Industrial Plant Power Distribution;
Technical Parameters 1: Rated Insulation Voltage;
Technical Parameters 2: Rated Frequency;
|