| Specification |
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Food Analysis;
Gaspath System: Double;
Detector: Sev P10;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 680mm;
Chromatographic Column Diameter: 200mm;
Flow Range: 0.001-10.000ml/Min(Et Step Length 0.001ml/Min);
Flow Precision: Rsd<0.05%;
Max Pressure: 42MPa;
Accuracy: ≤±0.25%(0.001-10ml/Min);
Gradient: 2 or 3;
Dimension: 400mm*300mm*180mm;
Wavelength Range: 190-700nm;
Power Supply: AC 110V/220V, 50Hz/60Hz;
|
After-sales Service: Online Video Service;
Warranty: One Year;
Appliance: Medical Research;
Ray Type: Other;
Detector: Other;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 2~5mm;
Flow Accuracy: ≤±0.3% (1.00ml/Min, H2O,R.T.,8.5MPa);
Flow Range: 0.001ml/Min-10.000ml/Min;
Pump Type: Binary High-Pressure Constant Flow Pump;
Flow Stability: Rsd≤0.1% (1.00ml/Min, H2O,R.T.,8.5MPa);
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
|
After-sales Service: Yes;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: N/a;
Spectrometer Detector: UV;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: ID16*25mm;
Chromatographic Column Diameter: ID16*25mm;
Separation Result: Good Alternative;
Recommend It to Any Lab: Yes;
|