| Specification |
Application: Power, Electronic, Instrument, Lighting, Audio;
Phase: Single;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Auto-transformer;
Usage: Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EE;
Brand: AL;
Inductance: 250uh ± 20%;
Input Voltage: 40V to 56V;
Work Frequency: 200kHz;
Output Current: 10A;
Specification.: 21*25*10.5;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer, Cast Resin Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: EI;
Brand: Hwh;
Rated Capacity: 30-2500kVA;
High Voltage: 6-11kv 6-11kv;
Low Voltage: 0.4kv;
Impedance Voltage: 4.0-8.0%;
Connected Group Label: Dyn11 or Yyn0;
Rated L.V.: 0.4/0.415/0.42/0.433/0.46/0.48kv;
Input Voltage: 10kv, 15kv, 35kv, 20kv, 40.5kv, 13.8kv;
Output Voltage: 220V, 380V, 400V , 415V, 240V, 360V, 600V;
Frequency: 50/60Hz;
Optional Accessories: Temperature Control, Fans, Enclosures, CT;
No Load Loss: Customized;
Load Loss (@120°c): as Technical Specification;
Load Loss (@75°c): as Technical Specification;
Installation Height: <=1000m;
Winding Material: Copper or Aluminum;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Oil-immersed Type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer, Distribution Transformer;
Frequency Characteristics: Power Frequency;
Shape of Core: U;
Reference Standards: IEC 60076;
Voltage (Hv) (Kv): 11 Kv;
Core Material: Silicon Steel;
Temperature Rise (W): 60/65K;
Insulation Class: a-Class;
Lightning Impulse Withstand Voltage: as Per IEC Standard;
Rated Capacity: 500 kVA;
Cooling Way: Onan/Onaf;
|
Application: Power;
Phase: Three;
Core: Core-type Transformer;
Cooling Method: Dry-type Transformer;
Winding Type: Two-winding Transformer;
Usage: Power Transformer;
Frequency Characteristics: Low Frequency;
Shape of Core: EI;
Brand: Ville;
Capacity: 5kVA;
Frequency: 50Hz;
Input Voltage: 380V;
Output Voltage: 380V;
Winding: Copper;
|