| Specification |
Application: Electronic, Instrument, Position Sensor;
Type: Rogowski Coil;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Coil Structure: Toroidal;
Secondary Output: Customized;
Accuracy: 0.5/1 Class;
Operation Temp: - 25 to + 75c;
Primary Input: Customized;
Lead Wire: According to Customer Requirements;
Coil Length: 20cm-200cm;
Frequency: 50/60Hz;
Insulation Strength: 3kv;
Inner Diameter: 16~51mm;
|
Application: Electronic, Instrument;
Type: Voltage Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Power Supply;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Weight: 30kg;
Rated Frequency: 50Hz or 60Hz;
Power Factor: Cosφ=0.8(Lag);
Ambient Temperature: -5℃~+40℃;
Insulation Level: 12/42/75kv,7.2/30/60kv;
|
Application: Electronic, Instrument, Current Measurement, Energy Metering, Other;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Insulating Medium: Epoxy Resin;
Installation: Indoor Switchgear, Control Panels, Other;
Rated Voltage: 12kv;
Rated Frequency: 50Hz / 60Hz;
Structure: Fully Enclosed Resin-Molded Body;
Features: Lightweight, Omni-Directional Installation;
Environmental Capability: Resistant to Humidity and Pollution;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Polycarbonate Plastic;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Weight: 500;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Ambient Temperature: -5℃~+40℃;
|
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Frequency: 50Hz;
Rated Voltage: 12 Kv;
Rated Current: 630A;
|