| Specification |
Application: Electronic, Instrument, Position Sensor;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Coil Structure: Toroidal;
Secondary Output: 0-500mA/1A/5A/333mv;
Primary Input: 5A-10ka;
Frequency: 50/60Hz;
Accuracy: Support Custom;
Inner Diameter: Support Custom;
Lead Wire: According to Customer Requirements;
Operation Temp: - 25 to + 75c;
Insulation Strength: 3kv;
|
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Relay Prodtion HVAC;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Accuracy Class: 0.5 1.0s: Ratio : 3000:1;
Protection: 5 Times Protection, 10 Times Protecti;
Split Core Current Transformer: 0.333-3.53V Rated Secondary Output;
Application 1: Current, Power, Energy, Monitoring Devices;
Application 2: Power Factor Correction Devices.;
Rated Load: 1, 2.5, 5.0, 10, 30va;
Highest Voltage for Equipment Um (RMS): 720 VAC;
Frequency Range: 50/60Hz;
Rated Power-Frequency Withstand Voltage;: 3, 000 VAC;
Output Split Core CT: Standard:IEC 60044-1;
Name: Current Probe;
Product1: Split CT Transformer;
Product2: ETL Current Probe Transformer;
Product 3: 600A 100A 5A Split Core CT;
|
Application: Electronic, Instrument, Audio, Lighting;
Type: Toroidal Style Split Core Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement, Electronic, Instrument, Position Sensor, Audio;
Winding Form: Single Layer & Tightly Wound Type;
Installation: Wire Leads;
Voltage Transformation Principle: 0.333V Output Voltage 0-500mA;
Core: Core-Type Transformer;
Cooling Method: Dry-Type Transformer;
Winding Type: Multi-Winding Transformer;
Frequency Characteristics: 50/400Hz;
Brand: Grewin;
Shape of Core: Single Stage Type;
Protection: 5 Times Protection, 10 Times Protecti;
Rated Load: 1, 2.5, 5.0, 10, 30va;
Frequency Range: 50/400Hz;
Output Split Core C: Standard:IEC 60044-1;
|
Application: Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Insulating Paper;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Primary Input Current: 5-6300A;
Secondary Output Current: 5A, 1A, 0.1A, 0.05A;
Rated Voltage: AC0.66kv=AC0.69kv;
Frequency: 50-60Hz;
Altitude: 3000m;
|
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Outdoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Type1: Current Transformer;
|