| Specification |
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Eight Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Automation Type;
Excitation Mode: AC Rotating Exciter;
Rated Voltage: 220V, 230V, 240V, 440V, 460;
Per Speed: 1500/1800rpm;
Frequency: 50/60Hz;
Optional Type: Open or Silent Type;
Alternator: Stanford/Marathon;
Rated Current: 264AMP-864AMP;
|
After-sales Service: Yes;
Warranty: 3months-1year;
Type: Self-Starting Diesel Generator;
Installation Method: Portable;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: 24V DC Electric Start;
Speed: 1800rpm;
Conditions of Use: Land Use;
Usage: Common Units;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Frequency: 50Hz/60Hz;
Rated Current: 902A;
Rated Voltage: 230V,400V;
ATS: Optioal;
Rated Power: 500kw;
|
After-sales Service: Supported;
Warranty: 1000 Hrs or 12 Months Whichever Comes First;
Type: Self-Starting Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Marine;
Usage: Common Units, Standby Unit, Emergency Crew, Power Solution;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Free: Customize Design Service;
Enclosure: Container Type;
Frequency: 50Hz/60Hz;
Voltage: 110-480V;
|
After-sales Service: Remote Technical Guidance;
Warranty: 1 Year;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units, Standby Unit, Emergency Crew;
Landuse Type of Unit: Ordinary;
Excitation Mode: AC Rotating Exciter;
Normal Power (Kw): 810-1000kw;
Normal Speed (R/Min): 1300-1500;
Total Piston Displacement (L): 71.45;
|
After-sales Service: 1 Year/1000 Hours;
Warranty: 1 Year/1000 Hours;
Type: Basic Diesel Generator;
Installation Method: Fixed;
Stroke: Four Stroke;
Cooling Method: Water Cooling;
Output Type: AC Three Phase;
Conditions of Use: Land Use;
Usage: Common Units;
Landuse Type of Unit: Low Noise Automation Type;
Excitation Mode: AC Rotating Exciter;
Engine: with Cummins Engine;
Engine Model: Kta38-G2;
Alternator: Leroy Somer or Equivalent;
Alternative: with ATS Cabinet;
Tank: 8 Hours' Base Fuel Tank or External;
Voltage: 440V/254V 3 Phase;
Frequency: 60Hz;
|