| Specification |
After-sales Service: Online Technical Support;
Application: X-ray Spectrometer;
Warranty: 1 Year;
Detection Method: Spectrograph;
Advantage: High Sensitive;
Principle: New Spectrometer;
Wavelengths: Polychromator;
Dispersive Element: Interferometer Spectrometer;
Light Number: Polychromator;
Customized: Non-Customized;
Parameter: Alloy Application;
Model: Truex 800;
Production Speed: 300 Piece Per Year;
Package Size: 58.00cm * 27.00cm * 98.00cm;
Package Gross Weight: 49000kg;
|
After-sales Service: Life Long Term Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Visible Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
Name: Visible Spectrophotometer;
Photometry: Split Beam;
Monochromator Type: Czerny-Turner;
Focal Length: 160mm;
Grating: 1200 Lines/mm;
Detector: Silicon Photocell;
Spectrum Bandwidth: 5nm;
Wavelength Setting: Manual Turn Knob;
Wavelength Range: 340-1000nm;
Wavelength Accuracy: ±2nm;
Wavelength Repeatability: ≤1nm;
Stray Light: ≤0.5%T(at 360nm Nano2);
Power: AC220V±22V 50Hz±1Hz, 130W;
|
After-sales Service: Life Long Term Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Visible Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
Name: Adjustable Fluorescence Spectrophotometer;
Light Source: The Light Source;
Monochromator: C-T Diffraction Grating Monochromator;
Emission Wavelength Accuracy: ±2nm;
Emission Wavelength Repeatability: ≤1nm;
Sensitivity: Quinine Sulfate Detection Limit Is 5×10-10;
Linear Correlation Coefficient: ≥ 0.995;
Zero Drift: ±0.3% (Within 10 Min);
Peak Intensity Reproducibility: ≤ 1.5%;
Supply Voltage: 220V±22V, 50Hz±1Hz;
Power: 100W;
|
After-sales Service: Life Long Term Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Visible Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
Name: Flame Photometer;
Operation Mode: 7- Inch Color Touch- Screen;
Display Value: Concentration Value;
Data Range: 0000-9999;
Testable: K, Na;
Channel Qty: 2;
Range Ppm: K 0-100,Na 0-160;
Lod Ppm: K 0.01,Na 0.01;
Linear Error: K 0.195, Na 0.69;
Response Time: <8s;
Sample Uptake: <6ml/Min;
Stability: < 3% Drift Over15s When Continuously Aspirating.;
Reproducibility: < 3% Coefficient of Variation for 7 Consecutive SA;
Power: AC220V±22V 50Hz±1Hz,250W;
|
After-sales Service: Life Long Term Technical Support;
Application: Laboratory Apparatus;
Warranty: 1 Year;
Detection Method: Spectrophotometer;
Advantage: High Sensitive;
Principle: Classic Spectrometer;
Wavelengths: Visible Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Non-Customized;
Name: Flame Photometer;
Operation Mode: 7- Inch Color Touch- Screen;
Display Value: Concentration Value;
Data Range: 0.000-999.9;
Testable: K, Na, Li, Ca;
Channel Qty: 4;
Range Ppm: K 0-100,Na 0-160,Li 0-100,Ca 0-1000;
Lod Ppm: K 0.01,Na 0.01, Li 0.1,Ca 2;
Linear Error: K 0.195, Na 0.69,Li 0.15, Ca 3;
Response Time: <8s;
Sample Uptake: <6ml/Min;
Stability: < 3% Drift Over15s When Continuously Aspirating.;
Reproducibility: < 3% Coefficient of Variation for 7 Consecutive;
Power: AC220V±22V 50Hz±1Hz,250W;
COM: USB;
|