| Specification |
After-sales Service: 1 Years;
Warranty: Yes;
Wavelength Range: 400~700nm;
Optical Geometry: 45/0;
Weight: About 600g;
Data Port: USB, Bluetooth 5.0;
Aperture: One Aperture: 2mm, 4mm, 8mm Optional;
|
After-sales Service: Life-Long Maintenance Service;
Warranty: 1-Year;
Maximum Test Force: 1000n;
Overall Accuracy Class: 0.5 Grade;
Effective Force Measurement Range: 0.2%~100%;
Force Measurement Accuracy: ±0.005 of Indicated Value;
Power System: Servo Motor;
Transmission System: High-Precision Ball Screw;
Test Stroke: 800mm (Can Be Increased Upon Request);
Test Speed Range: 0.01~500mm/Min;
Displacement Measurement System: Photoelectric Encoder;
Displacement Measurement Accuracy: ±0.005 of Indicated Value;
Test Bench Safety Device: Electronic Limit Protection, Emergency Stop Switch;
Overload Protection: Automatic Protection When Exceeding 10% of Max Loa;
Fixture Configuration: Standard or Customized;
Motor: 220V, 400W;
Net Weight: 100kg;
|
After-sales Service: Life-Long Maintenance Service;
Warranty: 1-Year;
Maximum Test Force: 1000n;
Overall Accuracy Class: 0.5 Grade;
Effective Force Measurement Range: 0.2%~100%;
Force Measurement Accuracy: ±0.005 of Indicated Value;
Power System: Servo Motor;
Transmission System: High-Precision Ball Screw;
Test Stroke: 800mm (Can Be Increased Upon Request);
Test Speed Range: 0.01~500mm/Min;
Displacement Measurement System: Photoelectric Encoder;
Displacement Measurement Accuracy: ±0.005 of Indicated Value;
Test Bench Safety Device: Electronic Limit Protection, Emergency Stop Switch;
Overload Protection: Automatic Protection When Exceeding 10% of Max Loa;
Fixture Configuration: Standard or Customized;
Motor: 220V, 400W;
Net Weight: 100kg;
|
Warranty: One Year;
Measuring Unit: μm/(PA·s)/Ml, Ml/Min, S/100;
Flow Range: 0~5000ml/Min;
Pressure Adjustment Range: 0.01~3kpa, Adjustable;
Regular Pressure 1: Schopper Method: 1kpa;
Regular Pressure 2: Gurley Method: 1.22kpa;
Regular Pressure 3: Bendtsen Method: 1.47kpa;
Effective Test Area: 6.42cm2/10.0±0.2 Cm;
Pressure Difference Adjustment Method: Automatic;
Test Time Setting Range: 0-999s;
Control Method: Touch Screen(Computer Control System Optional);
Air Source: External;
Sample Clamping Method: Automatic;
Sample Clamping Pressure: 0.05~6kpa;
Data Communication Interface: USB;
Test Method: Schober/Gurley/Bentsen;
|
Warranty: One Year;
Measuring Unit: μm/(PA·s)/Ml, Ml/Min, S/100;
Flow Range: 0~5000ml/Min;
Pressure Adjustment Range: 0.01~3kpa, Adjustable;
Regular Pressure 1: Schopper Method: 1kpa;
Regular Pressure 2: Gurley Method: 1.22kpa;
Regular Pressure 3: Bendtsen Method: 1.47kpa;
Effective Test Area: 6.42cm2/10.0±0.2 Cm;
Pressure Difference Adjustment Method: Automatic;
Test Time Setting Range: 0-999s;
Control Method: Touch Screen(Computer Control System Optional);
Air Source: External;
Sample Clamping Method: Automatic;
Sample Clamping Pressure: 0.05~6kpa;
Data Communication Interface: USB;
Test Method: Schober/Gurley/Bentsen;
|