Basic Info.
Chromatography Type
Liquid Chromatography
Product Description
Input channel count: 2;
Communication: RS-232;
Brand Name: Surwit
Model: N2000 (4.0 version)
Certificate: GB/T 19001-2008/ISO 9001: 2008
Can be connected to all chromatography system, such as GC, HPLC, CPC, IC, CE, and it can replace all traditional recorder and integrator as well.
External type
Edit Data
Features and Specification
A1. Specifications of N2000 Chromatography Data System
General
Number of Channels: 2
Input Voltage: -5 mV ~ 1.7 V
Input Resistance: > 10 MW
Sensitivity of Integration: 1 mV-sec
Dynamic Range: 107
Linearity: ~ 0.1 %
Peak Processing
Number of peaks: > 1000
Width of peak: 0.1 sec
Automatic Time Programming
Manual Integration enabled
Automatic identification of complex peaks and precise partition of overlapped peak
Automatic tracing and correcting base line
Automatically eliminate the affect of negative peak
Meet the GMP regulation
Methods for Identifying Peak
Conservative time method
Components table method
Parameters for Integration
Peak area
Peak height
Method for Quantitative Calculation
1. Normalized Method,
2. Normalized Method with Proportional Factor,
3. Internal Standard Method,
4. Grouping Method,
5. Multiple Internal Standard Method,
6. External Standard Method,
7. Logarithmic Method.
A2. System Requirements
Hardware Computer
IBM or 100% compatible (P-1 or higher)
CPU: 166 MHz or faster
Memory: 32M Bytes or more
Disk Drive: 1 hard disk, 1 CD-ROM drive, 1 or 2 floppy disk drives
Monitor: VGA display and graphics card 256 colors, 1024 by 768 pixels
Mouse: Bus or serial mouse
Printer (optional): Any printer that works with Microsoft Windows
Software Windows
Microsoft Windows 95/98 or later
Internet Explorer 4.0 or later
Other Misc. Hardware
22-bit high performance ADC card
Terminal panel and cover
Item Description
The N2000 Photographic Data Workstation is a software package to install which on your personal computer will allow you to control your chromatography and analyze the data received from it.
Your personal computer then becomes a sophisticated chromatography integrator and a data storage device.
This Software allows you to:
1. Setup, modify, catalog, recall, and print data processing Methods.
2. Catalog and recall chromatographic data.
3. Analyze data by integrating to find, identify, and graph peaks.
4. Setup and run automated batches.
5. Graphically manipulate the displays via capabilities to zoom in / zoom out, split / unsplit screen, scroll, position relative cursors, track time and amplitude, and display baseline.
6. Graphically specify Timed Events.
7. Calculate, display, and print different kind of Reports, namely: The Area, Normalization, External Standard, and Internal Standard.
8. Create Customized Reports.
9. Export stored data through other data formats such that they can be used in other software packages such as Excel, Lotus 123, and debase III /IV.
10. Dynamically link with other Windows applications such as Microsoft Excel or Microsoft Word to exchange data.
The N2000+ Chromatography Data System is a chromatography software developed by Surwit Technology based on the traditional N2000 Data System. It supports 32-bit and 64-bit operating systems including XP, Win7, Win8, and Win10, with enhanced three-tier permission management. The software features more accurate automatic data calculation and improved chromatogram smoothness, resulting in further enhancements in user experience and application performance. Product features: 1. Enhanced functionality with three-level permission management Users have independent usernames and login passwords. The software includes authentication to verify complete installation. During configuration, hardware connections are detected via indicator lights for quick verification. Trigger methods include Start Only, Start-Start, and Start-Stop. 2. Automatic data calculation is more accurate With a sampling frequency of 40Hz, the spectrum achieves better smoothing and more accurate integration. Custom calculation formulas can be designed according to Chinese, American, European, and Japanese standards, along with four user-defined options. The correction curve provides three selectable modes: considering, passing, and ignoring the origin. The system automatically calculates relative deviations by summarization. 3. Humanized operating system Supports XP, Windows 7, Windows 8, and Windows 10 (32-bit and 64-bit operating systems). System logs can be searched and printed by time or operation content.
N2000 Chromatogram Data System (4.0 versions) is a data Data System which developed by Surwit Technology Inc. on the basis of numerous customer feedbacks, which fit to domestic and foreign chromatography instrument analog signals to accept, process and report.
N2000 adopts the latest production technology and high-quality components, on the basis of ensuring operation convenience, greatly improved the hardware reliability and anti-interference, which can be widely used in chemical industry, pharmaceutical, food, life sciences, mines, research institutes and universities laboratory, etc.
Compatibility
N2000 (4.0) can be connected to Shimadzu, Agilent, Waters and general chromatography instrument.
Original imported chip
The original imported conversion module chip ensures the highest accuracy.
Zero self-adjustment
Self adjustment to zero ensures the reproducibility of chromatographic analysis of non-influence temperature of collection card.
Automatic calibration function
Advanced dynamic memory can constantly record and calibrate data, reduce the error influence as much as possible.
Compared with different Versions
All is Dual Channel CDS
The package includes the following items: 1. One stand-alone 2-channel data handling unit. 2. One Chromatography data system on CD-ROM 3. One COM & USB cable. 4. One set of signal cables. 5. Two junction terminals. 6. One copy of User Manual in English.
Gross weight: 1 kg. Dimension: 30 x 20 x 6 cm.
N2000 CDS provides you with the best value data handling solution for upgrading your GC, flash chromatograph, biochromatograph, HPLC, and CE. Though priced at a fraction of an integrator, this PC-based chromatography data system offers the same power and performance as data systems that cost five to ten times more. l Replace paper records, integrators, and DOS-based systems. l No programming required - just plug and play l Export data for use with MS Word, Excel, Photoshop or CorelDraw
Specifications Number of channels: 2 Input voltage: -5 mV-1.7 V Input impedance: > 10 MW Dynamic range: 107 Linearity: 0.1% Mininum resolution: 1 uV Frequency of sampling: 10 or 50/sec Manual integration enabled Various methods for quantitative calculation Equipped with a remote starter to be connected to analytical instrument or Autosampler to receive the Start/Stop signals.
They have been tested to work perfectly when replacing integrators on a variety of chromatography equipment. For example: Waters 441, 480, 481, 484, 486, 490E, 2487 UV-Visible Absorbance Detector, Waters 470, 472 Fluorescence Detector, Waters 430,431 Conductity Detector, Waters R401, R404, 410, 2410, 2414 Differiential Refractometer or Refractive Index Detector, Waters 460, 464 Electrochemical Detector. Shimadzu SPD-6A, SPD-6AV, SPD-10A, SPD-10AV UV-Visible Absorbance Detector, Shimadzu RF-535, RF-551, FLD-6 Fluorescence Detector, Shimadzu GC-9A FID Detector, GC-Mini2 FID Detector. ABI or Kratos or Spectroflow 757, 759A, 783, 783A, 785A UV-Visible Absorbance Detector, ABI 980 Fluorescence Detector. Spectra-Physics, Thermo Separation Products, LDC SpectroMonitor I, III, D, 3100, 3200, 5000, Spectra 100, SpectraSystem UV1000, UV2000, Spectra Focus Scanning Absorbance Detector. Hitachi or Merck 628, 655A, L-4000, L-4250, L-7400, L-7420, L-7450 UV-Vis Detector, F-1000, F-1200, F-1050, F-7485 Fluorescence Detector. HP 1050 LC. Hewlett Packard or HP 5890 Gas Chromatograph. Gow-Mac Instruments 580, 600 Gas Chromatograph. SRI instruments 8610 Gas Chromatograph. Varian 3410, 3400, 3600, CP-3800 Gas Chromatograph. LabAlliance or SSI Model 500, Model 506 UV Vis Detector. Linear 200, 201, 205, 206PHD UV-Visible Absorbance Detector, LC-304 Fluorescence Detector. Knauer Variable Wavelength Monitor, Refrative Index Detector. Bio-Rad 1801 UV Monitor, Bio-Rad 1640 Electrochemical Detector, Bio-Rad 1755 Refractive Index Detector. Perkin Elmer LC-95, 785A UV-Visible Absorbance Dector, LC-25 RI Detector. LKB, Pharmacia, GE Single Path Monitor UV-1, UV-M II, Uvicord SII, 2151 UV-Visible Absorbance Detector. AKTA prime, AKTA prime plus. Alltech 500, Varex II, Varex MKIII ELSD, Sedex 55, Sedex 75 ELSD, Polymer Laboratories EMD-950 Mass Detector, Evaporative Light Scattering Detector. Dynamax Absorbance UV-1, UV-C, UV-D Detectors. Acutech 500 UV/Vis Absorbance Detector HPLC. Varian PorStar MODEL 350 Refractive Index RI Detector. Varian ProStar 320 Absorbance Detector. Viscotek LR40 Laser Refractometer. Precision Instruments IOTA 2 Refracative Index Detector. HP 1047A Refractive Index RI RID Detector. HP 1037A RID Refractive Index Detector. Dionex AD20, AD25 Absorbance Detectors. Du Pont 860 Absorbance Detector. ESA 520 Absorbance Detector. Erma ERC-7512 Refractive Index RI Detector. Activon Linear 200 Absorbance Detector. And a lot more to be added later. Please check back!
Can be used with NA 1500/1108 CARLO ERBA/FISONS/THERMO ORGANIC ELEMENTAL ANALYZER CHNS
Computer Requirements Windows 98, 2000, ME, XP, 7. The computer should have a minimum 64 MB RAM, both a serial and a USB port. Please note the system is compatible with 32-bit Windows operating systems but not 64-bit operating systems. This data system can be connected to a laptop PC Notebook equipped with a RS232 COM Port to PCMCIA Express Card Adapter. but not with a regular USB-COM adaptor. Please inquire if you have any questions. | | | |
| | | | |
| | | | |
| | | | |
Address:
6 F., No. 3 Building of Jinsheng Science Park, No. 611 Dongguan Rd., Hangzhou, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Industrial Equipment & Components, Instruments & Meters, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001
Company Introduction:
Company Profile
Surwit Technology Inc. is located in Hangzhou of China and specialized in various chromatographic analysis instruments, spectrometers and relevant data system.
Surwit Technology was originated from Zhejiang University intelligent information engineering institute.
Surwit integrate the research, development, product, sales and technical services as a whole.
The main product N2000 chromatogram data system occupies the biggest market share each year, nearly more than 8000 sets yearly, Customers have been reached to 100, 000 till 2010.
Main products:
Zhejiang University N2000 chromatography data system
N2000 USB chromatography data system
VI2010 chromatography data system
Survey chromatography data system
STI501 HPLC system
LC-10 Tvp liquid chromatography
Manual injector
HPLC Consumables
--------------------------------------
Company History
1998, N2000 CDS came out in Analysis Institute of Zhejiang University, first CDS in China.
2003, Sales of CDS increased to 5000 sets, which the first in China.
Import American technology, began to research of Model 500
2006, Surwit Technology Inc. Set up in Hangzhou, launched the STI501 HPLC System
2010, Launched VI2010, first countercharge CDS in China, accord with GMP Certification.
Open the oversea market.
2011, LC-10T HPLC system came to market
2012, LC-10T plus and STI 501 plus updated
2013, 1180 with the autosampler launched to market.
2016, OEM HPLC and GC CDS provided
Oversea market expanded to America, Italy, Japan, Brazil, Argentina, South Africa, India, Hungary and other countries.