| Specification |
Application: Industrial;
Warranty: 1 Year;
Detection Method: Spectrograph;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: Infrared Spectrometer;
Dispersive Element: Grating Spectrometer;
Spectral range: 900-1700nm;
Spectral channel number: 512;
Imaging speed: 740fps;
Spectral resolution (FWHM): <6nm;
Transmission efficiency: more than 60%;
stray light: less than 0.5%;
Slit width: 25um;
number of spatial pixels: 640;
exportation: start;
Camera interface: C-Mount;
attachments: USB3.0 transmission line;
|
After-sales Service: on Line Service;
Application: Photometric Measurement;
Warranty: > 1Year;
Detection Method: Spectroscopic;
Advantage: High Accuracy;
Principle: New Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Product Name: Spectrophotometer;
Model: Nbcs-500;
Geometry: D/8;
Light Source: LED;
Observer Angles: 2 Degree ;,10degree;;
Sensor: 256 Pixel CMOS Sensor;
Calibration: Auto;
Wavelength Interval: 10nm;
Wavelength Range: 400-700nm;
Sphere Size: 40mm;
Reflectance Range: 0-200%;
Reflectance Resolution: 0.01%;
Screen: IPS Full Color Screen,2.4 Inches;
Interface: USB Bluetooth;
Lamp Lifetime: 10 Years, 1 Million Tests;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Monochromator: Aberration-Corrected Czerny-Tumer Type Monochromat;
Wavelength Range: 185nm~910nm, Automatic Adjustment;
Raster Line Density: 1800 Lines/mm;
Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm, Five Levels with Automa;
Wavelength Indication Error: ±0.10nm;
Wavelength Repeatability Accuracy: Better Than 0.05nm;
Resolution: Better Than 0.3nm;
Baseline Drift: ±0.002ABS/30min;
Flame Atomizer Method: Flame, Graphite Furnace;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Monochromator: Aberration-Corrected Czerny-Tumer Type Monochromat;
Wavelength Range: 185nm~910nm, Automatic Adjustment;
Raster Line Density: 1800 Lines/mm;
Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm, Five Levels with Automa;
Wavelength Indication Error: ±0.10nm;
Wavelength Repeatability Accuracy: Better Than 0.05nm;
Resolution: Better Than 0.3nm;
Baseline Drift: ±0.002ABS/30min;
Flame Atomizer Method: Flame, Graphite Furnace;
|
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Application: Laboratory Apparatus;
Warranty: 1 Years;
Detection Method: Spectrophotometer;
Advantage: High Resolution;
Principle: Classic Spectrometer;
Wavelengths: UV Spectrometer;
Dispersive Element: Grating Spectrometer;
Light Number: Monochromator;
Customized: Customized;
Monochromator: Aberration-Corrected Czerny-Tumer Type Monochromat;
Wavelength Range: 185nm~910nm, Automatic Adjustment;
Raster Line Density: 1800 Lines/mm;
Spectral Bandwidth: 0.1, 0.2, 0.4, 1.0, 2.0nm, Five Levels with Automa;
Wavelength Indication Error: ±0.10nm;
Wavelength Repeatability Accuracy: Better Than 0.05nm;
Resolution: Better Than 0.3nm;
Baseline Drift: ±0.002ABS/30min;
Flame Atomizer Method: Flame, Graphite Furnace;
|