| Specification |
Application: Electronic, Instrument, Position Sensor, Lighting;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Phase: Single;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Active Type;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Capacitive Type;
Type: Split Core Current Transformer;
Model: Xh-Sct-T10;
Input Current: 80A;
Output: 26.67mA;
ID: 10mm;
Accuracy: 1.0 Class;
Withstanding Voltage(Hi-Pot): 3.5kv/1mA/1min;
Weight: 80g;
Color: Black;
MOQ: 10 PCS;
Lead Time: 3-7 Days;
Wire Cable: Twist Black& White;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Rated Dynamic Current (Ldyn): 2.5lth;
Rated Test Voltage: 3kv AC (1min);
Safe Factor: Fs 5;
Secondary Current: 5A / 1A;
Rated Insulation Voltage: AC 0.72kv;
Working Temperature: -10~+50;
Rated Frequency: 50/60Hz;
Continuous Overload: 1.2in;
Housing Self-Extinguishing Class: Vo;
Rated Short-Time Thermal Current (Lth): 60in;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Panel / DIN Rail / Busar;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Product Name: Current Transformer;
Antistop: Mes Current Transformer;
Reat Test Voltage: 3kv AC.(1 Min);
Terminals: Built-in Hinged Terminal Cover;
Safety Factor: Fs5;
Secondary Current: 5A / 1A;
Rated Voltage (Um): AC 0.72kv;
Operating Temperature: -10~+50 Degrees;
Rated Frequency: 50/60Hz;
Continuous Overload: 1.2in;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Common Insulating Materials;
Installation: Strut Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Antistop: Split Core Current Transformer;
Rated Test Voltage: 3kv AC (1min);
Safe Factor: Fs 5;
Secondary Current: 5A / 1A;
Rated Insulation Voltage: AC 0.72kv;
Working Temperature: -10~+50;
Rated Frequency: 50/60Hz;
Continuous Overload: 1.2in;
Size: 111*90 (20*32mm);
Warranty: 2years;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Common Insulating Materials;
Installation: Busbar Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Antistop: Split Core Current Transformer;
Rated Test Voltage: 3kv AC (1min);
Safe Factor: Fs 5;
Secondary Current: 5A / 1A;
Rated Insulation Voltage: AC 0.72kv;
Working Temperature: -10~+50;
Rated Frequency: 50/60Hz;
Continuous Overload: 1.2in;
Size: 146*116 (80*80mm);
Warranty: 2years;
|