| Specification |
Application: Electronic, Instrument, Position Sensor, Audio, Lighting;
Type: Current Transformer;
Phase: Three;
Operation Condition: Indoor;
Usage: Measurement;
Winding Form: Small Fixed Type;
Insulating Medium: Epoxy Resin;
Installation: Penetration Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Model: H-CT021-40d;
Rate Primary Current: 600A;
Max Primary Current: 720A;
Secondary Current: 5A;
Turns Ratio: 150:1;
Frequency: 50/60Hz;
Diameter: 31mm;
Certification Approved: RoHS, CE;
Manufacturer: Jiaxing Haihan Electron Co.,Ltd;
|
Application: Electronic, Instrument;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Epoxy Resin;
Installation: Busbar Type;
Magnetic Circuit Structure: Combined Type;
Operation Frequency: 50~60Hz;
Rated Input Current: 100A~5000A;
Rated Output Current: 1A, 5A;
|
Application: Electronic, Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|
Application: Electronic, Instrument;
Type: Common Mode Chokes;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Multilayer Honeycomb Type;
Insulating Medium: Common Insulating Materials;
Installation: PCB;
Magnetic Circuit Structure: Combined Type;
Voltage Transformation Principle: Electromagnetic Type;
Input: 25A;
Output: 0.47mh;
Operating Voltage: 600V AC 1000V DC;
Fire Resistance: UL94-V0;
Weight: 180g;
Certificates: CE/RoHS/Reach/ISO9001;
Color: Black;
|
Application: Electronic, Instrument, Metering;
Type: Current Transformer;
Phase: Single;
Operation Condition: Indoor;
Usage: Protection, Measurement;
Winding Form: Single Layer & Tightly Wound Type;
Insulating Medium: Epoxy Resin;
Installation: Extension Type;
Magnetic Circuit Structure: Single Stage Type;
Voltage Transformation Principle: Electromagnetic Type;
Insulation Level: 12/42/75kv;
Rated Secondary Current: 5A or 1A;
Rated Frequency: 50Hz or 60Hz;
Power Factor: CosΦ=0.8(Lag);
Altitude: Should Not Exceed 1000m;
Air Relative Site: Indoor;
|