| Specification |
Classification: 5-Part Auto Hematology Analyzer;
Type: Urine Analyzer;
Group: All;
Throughput: 60tests/Hour;
Assay Items: 5 Parts, 29parameters,3 Histograms, 3dscattergram;
Principle: Tri-Angle Laser Scatter;
Test Mode: Cbc Mode,Cbc+Diff Mode Venous Whole Blood, Capilla;
Sample Volume: Cbc+Diff Mode Less Than 20UL;
Storage: 10,000 Resultsincludinghistograms,Scattergrams and;
Interface: 4 USB Ports, 1LAN Port Bi-Direction Lis, Support H;
Package Size: 670*590*790mm(W*D*H);
Gross Weight: 53kg;
Reagent Package Size: 330*330*330mm , 400*290*240mm , 400*290*240mm;
Reagent Gross Weight: 22kg, 2kg, 1kg;
Power Supply: AC220V;
Wbc Linearity Range: (0~300.0X10^9)/L;
Rbc Linearity Range: (0~8.00X10^12)/L;
Hgb Linearity Range: (0~250)G/L;
|
Classification: ESR Analyzer;
Type: Biochemistry Analyzer;
Group: All;
Measuring Principle: Infrared Sensor;
Analysis: Westergren ESR Value(mm/Hr);
Throughput: up to 80 Samples Per Hour;
Reading Channels: 20;
Loading Capacity: 20 Samples at Same Time;
Loading Pattern: Random;
Measuring Time: 30 Minutes or 60 Minutes Selectable;
Sample Interval: 3 Minutes;
Measurement Range: (1-140)mm/H;
|
Classification: Semi-Auto Coagulation Analyzer;
Type: Biochemistry Analyzer;
Group: All;
Display: 4.3'';
Cuvette Incubation Positions: 5;
Reagent Incubation Positions: 2;
Wavelength: LED 470nm;
Sample Type: Plasma;
Results: 10000 Results Storage;
Sample Volume: 20-40μL;
Available Units: Seconds,Ratio, %, G/L;
Incubation Temperature: 37.0±1.0℃;
|
Classification: Auto Hematology Analyzer;
Type: Urine Analyzer;
Group: All;
Assay Items: 5 Parts, 29parameters,3 Histograms;
Testmode: Cbc Mode,Cbc+Diff Mode Venous Whole Blood, Capilla;
Sample Volume: Cbc+Diff Mode≤20μL Cbc Mode≤10μL;
Storage: 10,000 Resultsincludinghistograms,Scattergrams and;
Interface: 4 USB Ports, 1LAN Port Bi-Direction Lis, Support H;
Power Supply: AC220V±10% 50/60Hz; 110V±10% 60Hz;
Package Size: 670*590*790mm(W*D*H);
Gross Weight: 53kg;
Reagent Package Size: 320*320*290mm (W*D*H);
Reagentgross Weight: 22kg;
|
Classification: Auto Hematology Analyzer;
Type: Urine Analyzer;
Group: All;
Assay Items: 5 Parts, 28 Parameters, 2 Histograms, 2 Scattergra;
Test Mode: Cbc+5diff, Cbc;
Measuring Principle: Laser Scatter Technology;
Storage: 100, 000 Results Storage;
Lis Interface: Support Hl7 Protocol;
QC and Calibration: Multiple QC Rules, Including L-J, X-B etc. Auto;
Incubation: Integral Titanium Incubation System;
Multi-Warning: Reagent Inventory Check; Abnormal Original Data Wa;
Power Supply: AC220V±10% 50/60Hz; 110V±10% 60Hz;
Computer: External Optional;
|